Your browser doesn't support javascript.
loading
Confiabilidade das medidas de arquitetura do músculo Vasto Lateral pela ultrassonografia / Reliability of the measurements of architecture of the Vastus Lateralis muscle by ultrasonography
Marinho e Lima, Kelly Mônica; Oliveira, Liliam Fernandes de.
  • Marinho e Lima, Kelly Mônica; Universidade Federal do Rio de Janeiro. Escola de Educação Física e Desportos. Laboratório de Biomecânica Muscular. Rio de Janeiro. BR
  • Oliveira, Liliam Fernandes de; Universidade Federal do Rio de Janeiro. Escola de Educação Física e Desportos. Laboratório de Biomecânica Muscular. Rio de Janeiro. BR
Motriz rev. educ. fís. (Impr.) ; 19(1): 217-223, jan.-mar. 2013. ilus, tab
Article in Portuguese | LILACS | ID: lil-671479
RESUMO
As medidas de confiabilidade das análises da arquitetura muscular pela ultrasonografia são importantes referências para estudos aplicados de mecânica muscular. O objetivo deste estudo foi determinar a confiabilidade das medidas de espessura muscular (EM), ângulo de penação (AP) e comprimento da fibra (CF) do músculo Vasto Lateral (VL). As imagens de ultrassom foram obtidas em um grupo (N=14; 22 ± 1,75 anos) em duas visitas (sessenta medidas por indivíduo). Foi calculado o coeficiente de correlação intraclasse (CCI), coeficiente de variação (CV) e erro típico da medida (ETM). Os resultados demonstram alta confiabilidade CCI AP (0,83 a 0,99), EM (0,96 a 0,99) e CF (0,80 a 0,99); CV AP (3,68 a 6,34%), EM (3,12 a 3,84%) e CF (3,98 a 6,33%) e ETM AP (0,18 a 0,59º); EM (0,014 a 0,15mm) e CF (0,07 a 1,47mm). Essas medidas devem ser consideradas em estudos que analisam o impacto na arquitetura muscular em programas de condicionamento do Vasto Lateral.
ABSTRACT
Reliability of the measurements of the muscle architecture variables by ultrasound are important references for applied studies of muscle mechanics. The aim this study was to analyze the reliability of measurements of Vastus Lateralis (VL) muscle thickness (MT), pennation angle (PA) and fiber length (FL). Ultrasound images were obtained in two days (N=14, 22 ± 1,75 years) with a total of sixty measurements in each subject. Reliability was determined by intraclass correlation coefficient (ICC), coefficient of variation (CV) and typical error of measurement (TEM). Results show high reliability MT (0,96 a 0,99), PA (0,83 a 0,99) and FL (0,80 a 0,99) ICC; MT (3,12 a 3,84%), PA (3,68 a 6,34%) and FL (3,98 a 6,33%) CV; MT (0,014 a 0,15mm), PA (0,18 a 0,59º) and FL (0,07 a 1,47mm) TEM. These measures should be considered in studies of the impact of conditioning programs in the architecture of the vastus lateralis muscle.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Ultrasonics / Hip / Muscles Limits: Adult / Female / Humans / Male Language: Portuguese Journal: Motriz rev. educ. fís. (Impr.) Journal subject: Physical Education / Sports Medicine / MEDICINA FISICA E REABILITACAO Year: 2013 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal do Rio de Janeiro/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Ultrasonics / Hip / Muscles Limits: Adult / Female / Humans / Male Language: Portuguese Journal: Motriz rev. educ. fís. (Impr.) Journal subject: Physical Education / Sports Medicine / MEDICINA FISICA E REABILITACAO Year: 2013 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal do Rio de Janeiro/BR