Your browser doesn't support javascript.
loading
Tratamiento de la fractura de tibia mediante fijación externa: presentación de dos casos / Fracture treatment by mean of external fixation: presentation of two cases
Porto Álvarez, Roberto Fidel; Álvarez Núñez, Rudbeckia; Porto Álvarez, Godetia Madia.
  • Porto Álvarez, Roberto Fidel; Hospital Provincial Pediátrico Docente Eliseo Noel Caamaño. Matanzas. CU
  • Álvarez Núñez, Rudbeckia; Hospital Provincial Pediátrico Docente Eliseo Noel Caamaño. Matanzas. CU
  • Porto Álvarez, Godetia Madia; Hospital Provincial Pediátrico Docente Eliseo Noel Caamaño. Matanzas. CU
Rev. medica electron ; 35(3): 272-278, mayo-jun. 2013.
Article in Spanish | LILACS | ID: lil-679074
RESUMEN
Se presentaron dos casos que tuvieron fractura de tibia, a quienes se les colocaron fijadores externos bipolares RALCA, lo que brinda mayor estabilidad. En el primer caso, que fue una niña de 9 años politraumatizada con gran cantidad de traumas graves que permitió continuar las curas sin peligro de movilidad del foco de fractura, evitó abrir el foco de fractura y, por consiguiente, aumentar el sangramiento y el ulterior empeoramiento dentro de la gravedad del caso. En el segundo, permitió la movilización precoz del miembro inferior izquierdo y evitó la inmovilización con yeso prolongada. Se obtuvieron resultados satisfactorios en ambos casos, llegando a la conclusión de que la aplicación de esta técnica es sumamente útil, y evita operaciones demoradas que afecten el estado general del paciente.
ABSTRACT
We presented two cases who had tibia fracture, to whom we put bipolar external fixers RALCA, giving more stability. In the first case, a girl aged 9 years, politraumatized with a great quantity of serious trauma, it allowed to continue the treatment and healing without the danger of mobility in the fracture focus, avoiding the fracture focus opening and, therefore, the increase of bleeding and the farther worsening in the case seriousness. In the second case it allowed the precocious mobilization of the lower left limb and avoided the long immobilization with a cast. We obtained satisfactory results in both cases, arriving to the conclusion that this technical application is extremely utile and avoids delayed operations affecting the general status of the patient.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Tibial Fractures / External Fixators Limits: Child / Female / Humans / Male Language: Spanish Journal: Rev. medica electron Journal subject: Medicine Year: 2013 Type: Article Affiliation country: Cuba Institution/Affiliation country: Hospital Provincial Pediátrico Docente Eliseo Noel Caamaño/CU

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Tibial Fractures / External Fixators Limits: Child / Female / Humans / Male Language: Spanish Journal: Rev. medica electron Journal subject: Medicine Year: 2013 Type: Article Affiliation country: Cuba Institution/Affiliation country: Hospital Provincial Pediátrico Docente Eliseo Noel Caamaño/CU