Your browser doesn't support javascript.
loading
Stent aórtico pulsátil: uma nova alternativa na assistência ventricular crônica / Pulsatile stent graft: a new alternative in chronic ventricular assistance
Palma, José Honório; Gaia, Diego Felipe; Caputi, Guido; Agreli, Guilherme; Breda, João Roberto; Braile, Domingo M.; Buffolo, Enio.
  • Palma, José Honório; Universidade Federal de São Paulo. São Paulo. BR
  • Gaia, Diego Felipe; Universidade Federal de São Paulo. São Paulo. BR
  • Caputi, Guido; Universidade Federal de São Paulo. São Paulo. BR
  • Agreli, Guilherme; Universidade Federal de São Paulo. São Paulo. BR
  • Breda, João Roberto; Universidade Federal de São Paulo. São Paulo. BR
  • Braile, Domingo M.; Universidade Federal de São Paulo. São Paulo. BR
  • Buffolo, Enio; Universidade Federal de São Paulo. São Paulo. BR
Rev. bras. cir. cardiovasc ; 28(2): 217-223, abr.-jun. 2013. ilus
Article in Portuguese | LILACS | ID: lil-682432
RESUMO
OBJETIVO: A insuficiência cardíaca é uma das causas mais comuns de internação. Dispositivos para assistência circulatória crônica foram testados e, em sua maioria, são de alta complexidade. O objetivo deste estudo é a descrição de uma endoprótese contrátil com capacidade de pulsação crônica no interior da aorta descendente, de maneira semelhante à produzida pelo balão intra-aórtico. MÉTODOS: Endopróteses pulsáteis compostas de níquel-titânio foram posicionadas de forma a envolver tubos de látex, simulando a aorta. Diferentes correntes elétricas foram aplicadas a unidades ligadas em série, de modo a causar contração da estrutura e deslocamento de uma coluna líquida. Foram realizadas duas sequências de testes: a primeira com duas gaiolas metálicas e a segunda com cinco gaiolas. Na primeira sequência de testes, aplicou-se tensão de 16,3 volts e corrente de 5 amperes e, na segunda sequência, tensão de 15 volts e corrente de 7 amperes. RESULTADOS: Na primeira sequência de testes, obteve-se o efeito pulsátil dos 2 stents, havendo contração do tubo e deslocamento da coluna d'água suficientes para validar o efeito pulsátil da endoprótese. As duas estruturas ejetaram um volume de 2,6 mL por ciclo, com uma variação de 29 mm na altura da coluna de água, equivalente a 8% de contração durante a pulsação. Na segunda sequência, conseguiu-se uma variação de 7,4 mL por ciclo. CONCLUSÃO: Os resultados obtidos comprovam a contratilidade da endoprótese pulsátil ativada pela aplicação de corrente elétrica. Continuidade do estudo e aperfeiçoamento do material se fazem necessários para obtenção de modelo mais eficiente do ponto de vista energético e com maior pulsação, para permitir volumes de ejeção comparáveis aos de balões intra-aórticos.
ABSTRACT
OBJECTIVE: Heart failure is currently one of the most common hospitalization causes. Several chronic circulatory assist devices have been tested and are highly complex. The objective is the description of a pulsatile endoprosthesis capable of applying a chronic pulse within the descending aorta, similar to that produced by intra-aortic balloon. METHODS: Pulsatile stents composed of nickel-titanium were built and positioned to engage latex tubes simulating the aorta. Different electric currents were applied to units connected in series in order to cause structure contraction and displacement of a liquid column. There were two sequence tests: first composed of two metallic cages and the second composed of five cages. At first sequence tests was applied a voltage of 16.3 volts and a current of 5 amperes. In the second, voltage of 15 volts and current of 07 amperes. RESULTS: In the first sequence was obtained the pulsatile effect of stent, with contraction of the tube and displacement of the water column sufficient to validate the pulsating effect of the endoprosthesis. The two structures ejected a volume of 2.6 ml per cycle, with a range of 29 mm in height of the column of water equivalent to 8% shrinkage during the pulse. In the second sequence, it reachead a variation of 7.4 mL per cycle. CONCLUSION: The results obtained confirm the stent pulsatile contractility activated by electrical current. The continuity of the study and material improvement are necessary to obtain more efficient model from the point of view of energy and pulse, to allow ejection volumes comparable with the intra-aortic balloons.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Prosthesis Design / Pulsatile Flow / Stents / Heart-Assist Devices / Heart Failure Type of study: Prognostic study Limits: Humans Language: Portuguese Journal: Rev. bras. cir. cardiovasc Journal subject: Cardiology / General Surgery Year: 2013 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal de São Paulo/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Prosthesis Design / Pulsatile Flow / Stents / Heart-Assist Devices / Heart Failure Type of study: Prognostic study Limits: Humans Language: Portuguese Journal: Rev. bras. cir. cardiovasc Journal subject: Cardiology / General Surgery Year: 2013 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal de São Paulo/BR