Trepanación corneal cónica como nuevo perfil de corte para las queratoplastias penetrante y lamelar anterior / Conic corneal trephination as a new cutting profile for penetrating and anterior lamellar keratoplasties
Capote Cabrera, Armando; Cárdenas Díaz, Taimi; Cruz Izquierdo, Dunia; Hernßndez López, Iván; Vinardell Pérez, Susana; Ravelo Vázquez, Wina.
  • Capote Cabrera, Armando; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Cárdenas Díaz, Taimi; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Cruz Izquierdo, Dunia; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Hernßndez López, Iván; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Vinardell Pérez, Susana; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Ravelo Vázquez, Wina; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
Rev. cuba. oftalmol ; 26(1): 15-29, ene.-abr. 2013.
Article in Spanish | LILACS | ID: lil-683090
RESUMEN

Objetivos:

describir las características y empleo de la trepanación corneal cónica.

Métodos:

se realizó un estudio experimental en el Instituto Cubano de Oftalmología Ramón Pando Ferrer de enero a diciembre de 2010. Se realizó la trepanación en diez globos oculares no útiles para trasplante, con un trépano corneal de vacío que tiene como característica fundamental la creación de un corte oblicuo. Se analizaron los parámetros longitud del corte, grosor corneal, diámetro externo del botón, diámetro interno del botón y ángulo del corte. Se utilizó la estadística descriptiva para expresar los resultados.

Resultados:

la longitud media del corte fue de 1 776,7 ± 273,7 mm y el grosor corneal medio a nivel del corte fue de 850,0 ± 119,2 mm, con una diferencia entre estos de 926 mm. El diámetro externo medio del botón corneal fue de 7,6 ± 0,2 mm y el interno de 8,5 ± 0,4 mm, con una diferencia de 0,9 mm. El ángulo de corte medio fue de 28,4 ± 2,1°. Se estableció una fórmula para calcular la longitud o profundidad del corte en base a la paquimetría media del círculo en el que se realizó la trepanación para un ángulo de corte determinado.

Conclusiones:

se obtuvo un corte regular, simétrico y de mayor longitud que el grosor corneal y con el aspecto cónico planificado. Dicho patrón de corte provee una mayor área de contacto y una tendencia autosellante
ABSTRACT

Objectives:

to describe the characteristics and use of the conic corneal trephination.

Methods:

an experimental study was performed in Ramón Pando Ferrer Cuban Institute of Ophthalmology from January to December 2010. Ten eyeballs not useful for transplantation underwent trephination, with a corneal vacuum trephine particularly designed to create an oblique corneal cut. The cutting length, the corneal thickness, the external diameter of the disc, the internal diameter of the disc and the cutting angle were the analyzed parameters. Descriptive statistics were applied to show the results.

Results:

the mean cutting length was 1776.7 ± 273.7 mm and the mean corneal thickness at the cutting point was 850.0 ± 119.2 mm , being the difference between them equals to 926 mm. The mean external diameter was 7.6 ± 0.2 mm and the internal diameter was 8.5 ± 0.4 mm, with a difference of 0.9 mm. The mean cutting angle amounted to 28.4 ± 2.1°. A formula was developed to calculate the cutting length or depth based on the mean pachymetry of the circle where the trephination is performed for a determined cutting angle.

Conclusions:

aregular symmetric cut was obtained, longer than the corneal thickness with the planned conic profile. Such cutting pattern provides a larger contact surface and self-sealing tendency
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Corneal Transplantation / Keratoplasty, Penetrating Limits: Female / Humans / Male Language: Spanish Journal: Rev. cuba. oftalmol Journal subject: Ophthalmology Year: 2013 Type: Article Affiliation country: Cuba Institution/Affiliation country: Instituto Cubano de Oftalmología Ramón Pando Ferrer/CU

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Corneal Transplantation / Keratoplasty, Penetrating Limits: Female / Humans / Male Language: Spanish Journal: Rev. cuba. oftalmol Journal subject: Ophthalmology Year: 2013 Type: Article Affiliation country: Cuba Institution/Affiliation country: Instituto Cubano de Oftalmología Ramón Pando Ferrer/CU