Causas da retirada não planejada da sonda de alimentação em terapia intensiva / Causes for the unplanned removal of the feeding tube in intensive care
Pereira, Sandra Regina Maciqueira; Coelho, Maria José; Mesquita, Ayla Maria Farias de; Teixeira, Anderson Oliveira; Graciano, Selma de Almeida.
  • Pereira, Sandra Regina Maciqueira; Universidade Federal do Rio de Janeiro. Escola de Enfermagem Anna Nery. Rio de Janeiro. BR
  • Coelho, Maria José; Universidade Federal do Rio de Janeiro. Escola de Enfermagem Anna Nery. Rio de Janeiro. BR
  • Mesquita, Ayla Maria Farias de; Universidade Estadual do Rio de Janeiro. Rio de Janeiro. BR
  • Teixeira, Anderson Oliveira; Universidade Federal do Rio de Janeiro. Escola de Enfermagem Anna Nery. Rio de Janeiro. BR
  • Graciano, Selma de Almeida; Universidade Estácio de Sá. Rio de Janeiro. BR
Acta paul. enferm ; 26(4): 338-344, 2013. ilus, tab
Article in Portuguese | LILACS, BDENF | ID: lil-691291
RESUMO

OBJETIVO:

Descrever as principais causas da perda da sonda de alimentação e analisar as ações que tiveram impacto para a redução desta intercorrência.

MÉTODOS:

Trata-se de um estudo transversal com dados secundários provenientes de 4228 pacientes/dia com sonda de alimentação.

RESULTADOS:

As causas da perda da sonda foram a retirada pelo paciente (50%) e obstrução da sonda (36%). Observadas a correlação da perda da sonda enteral com alterações da cognição dos pacientes (delirium e demência) e a incrustação de resíduos no lúmen da sonda.

CONCLUSÃO:

As principais causas de retirada da sonda de alimentação foram relacionadas ao paciente e à obstrução. As medidas proativas para evitar a obstrução da sonda foram impactantes no período em que foram aplicadas as demais medidas tiveram baixo impacto.
ABSTRACT

OBJECTIVE:

Describe the main causes for the loss of the feeding tube and analyze the actions that had an impact towards the reduction of this adverse event.

METHODS:

Cross-sectional study with secondary data from 4228 patients/day using a feeding tube.

RESULTS:

The main causes for the loss of the tube were removal by the patient (50%) and obstruction of the tube (36%). The correlation of the loss of the feeding tube with alterations in the patients' cognition (delirium and dementia) and the incrustation of residues in the lumen of the tube were observed.

CONCLUSION:

The main causes for the removal of the feeding tube were related to the patient and the obstruction. Proactive measures to prevent the obstruction of the tube had a good impact during the period in which they were applied, whereas other measures had low impact.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Enteral Nutrition / Quality Indicators, Health Care / Critical Care / Intubation, Gastrointestinal / Nursing Care / Nursing Service, Hospital Type of study: Etiology study / Observational study / Prevalence study / Risk factors Limits: Humans Language: Portuguese Journal: Acta paul. enferm Journal subject: Nursing Year: 2013 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Estadual do Rio de Janeiro/BR / Universidade Estácio de Sá/BR / Universidade Federal do Rio de Janeiro/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Enteral Nutrition / Quality Indicators, Health Care / Critical Care / Intubation, Gastrointestinal / Nursing Care / Nursing Service, Hospital Type of study: Etiology study / Observational study / Prevalence study / Risk factors Limits: Humans Language: Portuguese Journal: Acta paul. enferm Journal subject: Nursing Year: 2013 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Estadual do Rio de Janeiro/BR / Universidade Estácio de Sá/BR / Universidade Federal do Rio de Janeiro/BR