Amplitude das emissões otoacústicas produto de distorção e o uso de contraceptivos hormonais: estudo preliminar / Amplitude of distortion product otoacoustic emissions and the use of hormonal contraceptives: preliminary study
Silva, Tatiana Rocha; Dias, Fernanda Abalen Martins.
  • Silva, Tatiana Rocha; Pontifícia Universidade Católica de Minas Gerais. Departamento de Fonoaudiologia. Belo Horizonte. BR
  • Dias, Fernanda Abalen Martins; Pontifícia Universidade Católica de Minas Gerais. Departamento de Fonoaudiologia. Belo Horizonte. BR
Audiol., Commun. res ; 18(4): 233-239, out.-dez. 2013. tab
Article in Portuguese | LILACS | ID: lil-697611
RESUMO

OBJETIVO:

Identificar se há diferença na amplitude das emissões otoacústicas de mulheres que utilizam e que não utilizam contraceptivo hormonal.

MÉTODOS:

Participaram da pesquisa 30 mulheres, sendo 15 que utilizam o método contraceptivo hormonal e 15 que não o utilizam, todos sem queixa auditiva e com audição dentro dos padrões de normalidade. A coleta de dados foi realizada por meio das emissões otoacústicas transientes e pelas emissões otoacústicas produto de distorção.

RESULTADOS:

Não houve diferença entre os valores de amplitude das emissões otoacústicas produto de distorção para as frequências de 1 kHz, 1,4 kHz, 2,8 kHz, 4 kHz e 6 kHz, na orelha direita, nos grupos estudados. Na frequência de 2 kHz houve tendência à diferença entre os valores de amplitude das emissões otoacústicas produto de distorção, comparando-se o grupo de mulheres que não usam contraceptivo hormonal e o grupo das que usam. Na orelha esquerda, não houve diferença entre os valores de amplitude das emissões otoacústicas produto de distorção para as frequências de 1 kHz, 1,4 kHz, 2 kHz, 2,8 kHz, 4 kHz e 6 kHz, nos dois grupos analisados.

CONCLUSÃO:

Não foram observadas diferenças na amplitude das emissões otoacústicas produto de distorção pelo uso de contraceptivo hormonal, nos grupos estudados.
ABSTRACT

PURPOSE:

To verify differences of otoacoustic emissions responses in women using and not using hormonal contraception.

METHODS:

Participated in this study 30 female individuals, 15 using a hormonal contraceptive method and 15 that do not use hormonal contraception. All without hearing complaints and hearing within normal limits. Data collection was performed by transient otoacoustic emissions and distortion product otoacoustic emissions.

RESULTS:

There was no difference between the amplitude of distortion product otoacoustic emissions for frequencies 1 kHz, 1.4 kHz, 2.8 kHz, 4 kHz and 6 kHz in the right ear between the groups. The frequency of 2 kHz tended to the difference between the amplitude of distortion product otoacoustic emissions between the group of women not using hormonal contraception and use. In the left ear there was no difference between the amplitude of distortion product otoacoustic emissions for frequencies 1 kHz, 1.4 kHz, 2 kHz, 2.8 kHz, 4 kHz and 6 kHz between the groups.

CONCLUSION:

No differences were observed in the amplitude of distortion product otoacoustic emissions by use of hormonal contraceptives.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Otoacoustic Emissions, Spontaneous / Contraceptive Agents, Female / Hair Cells, Auditory / Ear, Inner Limits: Female / Humans Language: Portuguese Journal: Audiol., Commun. res Journal subject: Speech-Language Pathology Year: 2013 Type: Article Affiliation country: Brazil Institution/Affiliation country: Pontifícia Universidade Católica de Minas Gerais/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Otoacoustic Emissions, Spontaneous / Contraceptive Agents, Female / Hair Cells, Auditory / Ear, Inner Limits: Female / Humans Language: Portuguese Journal: Audiol., Commun. res Journal subject: Speech-Language Pathology Year: 2013 Type: Article Affiliation country: Brazil Institution/Affiliation country: Pontifícia Universidade Católica de Minas Gerais/BR