Your browser doesn't support javascript.
loading
Simulação da distribuição de tensões em implante dentário curto com carregamento axial em corticais com diferentes espessuras / Simulation of stress distribution in short dental implant with axial loading in cortical with different thickness
Lehmann, Roberto Brunow; Elias, Carlos Nelson.
  • Lehmann, Roberto Brunow; Universidade Federal Fluminense. Departamento de Engenharia Mecânica. Niterói. BR
  • Elias, Carlos Nelson; IME. Rio de Janeiro. BR
Dent. press implantol ; 5(4): 46-54, Oct.-Dec. 2011. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-699634
RESUMO
Objetivo: avaliar o comportamento de implante curto inserido em osso cortical com diferentes espessuras. Métodos: foram realizadas simulações pelo método de elementos finitos com carregamento em implante curto (5,7 x 5,0mm) contendo hexágono externo. Ao todo, foram três modelos de simulação, um para cada espessura de osso cortical (1, 2 e 3mm). Resultados: quando o sistema foi inserido em um osso cortical de maior espessura, observou-se uma maior estabilidade e, consequentemente, menores tensões para o implante e componentes protéticos envolvidos. Conclusões: os resultados obtidos sugerem que o implante curto avaliado pode ser utilizado para as diferentes espessuras de osso cortical. Os valores de tensão obtidos foram sempre menores do que o necessário para induzir a deformação plástica do implante ou de qualquer componente do sistema protético. Para o osso cortical, as tensões foram menores do que o limite crítico apontado pela literatura para que ocorra a reabsorção óssea.
ABSTRACT
Objective: To evaluate the behavior of short implant inserted in cortical bone with different thicknesses. Methods: Simulations were performed by finite element method with loading on short implants (5.7 x 5.0 mm) containing external hexagonal. Three simulation models were built, one for each thickness of cortical bone (1, 2 and 3 mm). Results: When the system was inserted into a thicker cortical bone, there was an increased stability and, consequently, lower stresses to the implant and prosthetic components involved. Conclusions: The results suggest that the short implant assessed can be used for different thickness of cortical bone. The stress values obtained were always lower than the necessary to induce plastic deformation on implant or any component of the prosthetic system. On the cortical bone the stresses were lower than the critical values indicated in the literature for the occurrence of bone resorption.
Subject(s)

Search on Google
Index: LILACS (Americas) Main subject: Computer Simulation / Finite Element Analysis / Dental Implantation / Immediate Dental Implant Loading Language: Portuguese Journal: Dent. press implantol Journal subject: Dentistry Year: 2011 Type: Article Affiliation country: Brazil Institution/Affiliation country: IME/BR / Universidade Federal Fluminense/BR

Similar

MEDLINE

...
LILACS

LIS

Search on Google
Index: LILACS (Americas) Main subject: Computer Simulation / Finite Element Analysis / Dental Implantation / Immediate Dental Implant Loading Language: Portuguese Journal: Dent. press implantol Journal subject: Dentistry Year: 2011 Type: Article Affiliation country: Brazil Institution/Affiliation country: IME/BR / Universidade Federal Fluminense/BR