Evaluación de campo de la precisión de la prueba de diagnóstico rápido SD Bioline Malaria Antigen Pf/Pv® en Colombia / Field evaluation for diagnostic accuracy of the rapid test SD Bioline Malaria Antigen Pf/Pv® in Colombia
Mendoza, Nohora Marcela; Cucunubá, Zulma Milena; Aponte, Samanda; González, Nohora Elizabeth; Bernal, Sindy Durley.
  • Mendoza, Nohora Marcela; Instituto Nacional de Salud. Grupo de Parasitología. Bogotá. CO
  • Cucunubá, Zulma Milena; Instituto Nacional de Salud. Grupo de Parasitología. Bogotá. CO
  • Aponte, Samanda; Instituto Nacional de Salud. Grupo de Parasitología. Bogotá. CO
  • González, Nohora Elizabeth; Instituto Nacional de Salud. Grupo de Parasitología. Bogotá. CO
  • Bernal, Sindy Durley; Instituto Nacional de Salud. Grupo de Parasitología. Bogotá. CO
Biomédica (Bogotá) ; 33(4): 587-597, Dec. 2013. graf, tab
Article in Spanish | LILACS | ID: lil-700477
RESUMEN
Introducción. Las pruebas de diagnóstico rápido han sido postuladas como una forma de garantizar el diagnóstico de malaria, o paludismo, en zonas de difícil acceso. A pesar de su uso difundido, no hay estudios de campo que evalúen la precisión de la prueba de diagnóstico rápido SD Bioline Malaria Antigen Pf/Pv® en Colombia. Objetivo. Evaluar la precisión diagnóstica de la prueba de diagnóstico rápido SD Bioline Malaria Antigen Pf/Pv ®, en dos departamentos endémicos para malaria, comparando el diagnóstico con la gota gruesa corregida por reacción en cadena de la polimerasa (PCR). Materiales y métodos. Se trata de un estudio retrospectivo para evaluar sensibilidad, especificidad, valor diagnóstico positivo (VPP) y negativo (VPN), concordancia y límites de sensibilidad por rangos de parasitemia, de la prueba SD Bioline Malaria Antigen ® Pf/Pv, en Córdoba y Chocó. Los resultados fueron comparados con la gota gruesa corregida por PCR. Resultados. De 383 muestras procesadas, 121 fueron positivas (75 para Plasmodium vivax, 42 para P. falciparum y 4 para infección mixta) y 262 muestras negativas; los resultados obtenidos fueron los siguientes P. vivax sensibilidad, 92,0 % (IC 95% 83,6-96,3); especificidad, 98,7 % (IC 95% 96,7-99,5); VPP, 94,5 % (IC 95% 86,7-97,9); VPN, 98,1 % (IC 95% 95,8-99,1); IK, 0,90 (0,80-1,00). P. falciparum sensibilidad, 88,1 % (IC 95% 75,0-94,8); especificidad, 97,9 % (IC 95% 95,8-99,0); VPP, 84,1% % (IC 95% 70,6-92,1); VPN, 98,5 % (IC 95% 96,6-99,4); IK, 0,80 (0,70-0,90). Conclusiones. La prueba tuvo un buen desempeño, siendo mejor para P. vivax en comparación con que para P. falciparum. Persisten dificultades en la detección de bajas parasitemias. La falta de amplificación de los genes Pfhrp2 y Pfhrp3 en dos muestras con diagnóstico de como infección mixta, sugiere una posible deleción conjunta de estos genes.
ABSTRACT

Introduction:

Rapid diagnostic tests (RDT) have been postulated as a way to ensure access to malaria diagnosis in remote areas. Despite its widespread use, there are no field studies to evaluate the accuracy of the SD Bioline Malaria Antigen Pf/Pv in Colombia RDT.

Objective:

To evaluate the diagnostic accuracy of the SD Bioline Malaria Antigen Pf/Pv® RDT in two departments endemic for malaria, comparing diagnosis with thick film corrected with PCR. Materials and

methods:

A retrospective study was carried out to evaluate sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), concordance and sensitivity limits according to parasitemia ranges for the SD Bioline Malaria Antigen Pf/Pv ® test in Cordoba and Choco. The results were compared with microscopy corrected by PCR.

Results:

A total of 383 samples processed, 121 were positive (75 for P. vivax , 42 for P. falciparum and 4 for mixed infection) and 262 negative samples. P. vivax sensitivity 92.0% (95% CI 83.6-96.3), specificity 98.7% ( 95% CI 96.7-99.5), PPV 94.5% (95% CI 86.7-97.9), NPV 98.1% (95% CI 95.8-99.1), Cohen´s kappa coefficient was 0.90 (0.80-1.00). P. falciparum sensitivity 88.1% (95% CI 75.0-94.8), specificity 97.9% (95% CI 95.8-99.0), PPV 84.1% (95% CI 70.6-92.1), NPV 98.5% (95% IC 96.6-99.4), Cohen´s kappa coefficient 0.80 (95% CI 0.70-0.90).

Conclusions:

The test performed well, being better for P. vivax as compared to P. falciparum. There are still difficulties of RDT to detect low parasitemias. The non amplification of Pfhrp2 and Pfhrp3 genes in two samples diagnosed as mixed infection, suggest a possible deletion of these two genes together.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Plasmodium falciparum / Plasmodium vivax / Malaria, Vivax / Malaria, Falciparum / Antigens, Protozoan Type of study: Diagnostic study / Observational study / Prognostic study / Risk factors Limits: Adolescent / Adult / Aged / Aged80 / Child / Female / Humans / Male Country/Region as subject: South America / Colombia Language: Spanish Journal: Biomédica (Bogotá) Journal subject: Medicine Year: 2013 Type: Article Affiliation country: Colombia Institution/Affiliation country: Instituto Nacional de Salud/CO

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Plasmodium falciparum / Plasmodium vivax / Malaria, Vivax / Malaria, Falciparum / Antigens, Protozoan Type of study: Diagnostic study / Observational study / Prognostic study / Risk factors Limits: Adolescent / Adult / Aged / Aged80 / Child / Female / Humans / Male Country/Region as subject: South America / Colombia Language: Spanish Journal: Biomédica (Bogotá) Journal subject: Medicine Year: 2013 Type: Article Affiliation country: Colombia Institution/Affiliation country: Instituto Nacional de Salud/CO