Detección de Chlamydia trachomatis en muestras de exudado endocervical mediante una prueba de diagnóstico rápido y dos técnicas de reacción en cadena de la polimerasa / Detection of Chlamydia trachomatis in endocervical swab using rapid test and two reaction techniques polymerase chain
Rivero Figueroa, Dianelys; Kourí Cardellá, Vivian; Correa Sierra, Consuelo; Martínez Motas, Isabel; Llanes Caballero, Rafael; Barreal González, Rosa Teresita; García Vega, Edel.
  • Rivero Figueroa, Dianelys; Centro Municipal de Higiene y Epidemiología de 10 de Octubre. La Habana. CU
  • Kourí Cardellá, Vivian; Instituto de Medicina Tropical "Pedro Kourí". La Habana. CU
  • Correa Sierra, Consuelo; Instituto de Medicina Tropical "Pedro Kourí". La Habana. CU
  • Martínez Motas, Isabel; Instituto "Finlay". Centro de Investigación y Producción de Vacunas. La Habana. CU
  • Llanes Caballero, Rafael; Instituto de Medicina Tropical "Pedro Kourí". La Habana. CU
  • Barreal González, Rosa Teresita; Centro Municipal de Higiene y Epidemiología de 10 de Octubre. La Habana. CU
  • García Vega, Edel; Hospital Militar Central "Dr. Luis Díaz Soto". La Habana. CU
Rev. cuba. obstet. ginecol ; 40(1): 48-57, ene.-mar. 2014.
Article in Spanish | LILACS | ID: lil-706660
RESUMEN

Introducción:

Chlamydia trachomatis es el principal agente bacteriano que produce infecciones de transmisión sexual.

Objetivo:

detectar la presencia de C. trachomatis utilizando una prueba de diagnóstico rápido y compararla con la reacción en cadena de la polimerasa (RCP).

Métodos:

se procesaron 50 muestras de exudado endocervical, de mujeres sintomáticas del municipio 10 de Octubre. A las muestras se les aplicó la prueba Chlamy-check-1, un ensayo de RCP del gen del plásmido críptico y una RCP en tiempo real (RCP-TR) de la proteína mayor de la membrana externa (MOMP) de C. trachomatis, que fue utilizada como referencia. Se calculó, sensibilidad, especificidad, valor predictivo positivo (VPP) y negativo (VPN).

Resultados:

de las muestras estudiadas, 44 resultaron positivas por la prueba rápida, mientras que por la RCP del plásmido críptico solo 3 muestras (6 porciento) amplificaron. Al aplicar la RCP-TR, 4 muestras (8 porciento) se confirmaron como positivas, coincidiendo 3 por los tres métodos de diagnóstico. Al evaluar la prueba Chlamy-check-1 frente a la prueba de referencia se observó una sensibilidad de 100 porciento, mientras que la especificidad fue de 13 porciento, así como un VPP de 9,1 porciento y VPN de 100 porciento. Por el contrario, la RCP del plásmido críptico mostró una sensibilidad y especificidad de 75 y 100 porciento, respectivamente; un VPP de 100 porciento y VPN de 97,9 porciento.

Conclusiones:

se obtuvo diferencia entre los porcentajes de positividad detectados con la prueba rápida, y las técnicas de RCP. La baja especificidad de la prueba rápida indica la necesidad de realizar estudios de evaluación de este estuche diagnóstico.
ABSTRACT

Introduction:

Chlamydia trachomatis is the leading bacterial agent that causes sexually transmitted infections.

Objective:

to detect the presence of C. trachomatis using a rapid test and compare it with the chain reaction (PCR).

Methods:

50 endocervical exudates taken from symptomatic women were processed in Diez de October municipality. The samples were applied the Chlamy-check-1 test, a PCR assay of the cryptic plasmid gene and a real-time PCR (RT-PCR) of major outer membrane protein (MOMP) of C. trachomatis which was used as reference. Sensitivity, specificity, positive (PPV) and negative (NPV) predictive value were calculated.

Results:

44 samples were positive by the rapid test, whereas only three samples (6 percent) amplified by cryptic plasmid PCR. Applying RT-PCR, 4 samples (8 percent) were confirmed as positive, 3 samples matched with three diagnostic methods. In assessing the Chlamy-check-1 versus the reference test, 100 percent of sensitivity was observed, while the specificity was 13 percent> Also PPV was 9.1percent and NPV was 100 percent. On the contrary, the cryptic plasmid PCR had 75 and 100 percent of sensitivity and specificity respectively, 100 percent PPV and 97.9 percent NPV.

Conclusions:

the difference was obtained between the percentages of positivity detected with both the rapid test, and CPR techniques. The low specificity of the rapid test indicates the need for further studies to evaluate this diagnostic kit.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Chlamydia trachomatis / Polymerase Chain Reaction Type of study: Diagnostic study Limits: Female / Humans Language: Spanish Journal: Rev. cuba. obstet. ginecol Journal subject: Gynecology / Obstetrics Year: 2014 Type: Article Affiliation country: Cuba Institution/Affiliation country: Instituto "Finlay"/CU / Centro Municipal de Higiene y Epidemiología de 10 de Octubre/CU / Hospital Militar Central "Dr. Luis Díaz Soto"/CU / Instituto de Medicina Tropical "Pedro Kourí"/CU

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Chlamydia trachomatis / Polymerase Chain Reaction Type of study: Diagnostic study Limits: Female / Humans Language: Spanish Journal: Rev. cuba. obstet. ginecol Journal subject: Gynecology / Obstetrics Year: 2014 Type: Article Affiliation country: Cuba Institution/Affiliation country: Instituto "Finlay"/CU / Centro Municipal de Higiene y Epidemiología de 10 de Octubre/CU / Hospital Militar Central "Dr. Luis Díaz Soto"/CU / Instituto de Medicina Tropical "Pedro Kourí"/CU