Your browser doesn't support javascript.
loading
Fatores que interferem no desempenho de usuários de implante coclear em testes de percepção de fala / Factors affecting the performance of users of cochlear implant in speech perception testing
Meneses, Michelle Sales de; Cardoso, Carolina Costa; Silva, Isabella Monteiro de Castro.
  • Meneses, Michelle Sales de; Centro Educacional da Audição e Linguagem ? Ludovico Pavoni. Brasília. BR
  • Cardoso, Carolina Costa; Centro Educacional da Audição e Linguagem ? Ludovico Pavoni. Brasília. BR
  • Silva, Isabella Monteiro de Castro; Centro Educacional da Audição e Linguagem ? Ludovico Pavoni. Brasília. BR
Rev. CEFAC ; 16(1): 65-71, 03/2014. tab, graf
Article in Portuguese | LILACS | ID: lil-707215
RESUMO

Objetivo:

analisar os fatores que interferem no desempenho de usuários de implante coclear em testes de percepção de fala.

Métodos:

foram aplicados questionários e testes de percepção de fala em 25 indivíduos, de ambos os sexos, portadores de perda auditiva neurossensorial e usuários de IC unilateral.

Resultados:

- 48% dos participantes atingiram bom desempenho nos resultados dos testes de percepção de fala, apresentando porcentagens maiores ou iguais a 50 % de acertos. - Os participantes que obtiveram melhores resultados não são necessariamente os que possuem maior idade auditiva. - Dos 12 participantes que atingiram desempenho acima de 50%, 10 (83,3%) foram implantados mais precocemente (até 5 anos). - O uso do AASI na orelha contralateral influenciou significantemente nos índices de reconhecimento das palavras ou sentenças. - Os participantes que iniciaram o uso de AASI mais cedo não foram necessariamente os que apresentaram melhores resultados nos testes.

Conclusão:

a ativação mais precoce dos IC mostrou-se uma variável importante no desempenho dos testes. - O uso do AASI na orelha contralateral influenciou significantemente nos índices de reconhecimento das palavras ou sentenças.
ABSTRACT

Purpose:

to analyze the relation between speech perception tests in cochlear implant users.

Methods:

questionnaires and speech perception tests were applied in 25 individuals from both genders with sensorioneural hearing loss and users of unilateral cochlear implant.

Results:

48% of the participants had a good performance (50%) on speech perception tests. The participants who had the best results are not the ones with higher auditory age. 12 participants had a score higher than 50% and 10 (83%) of those, did the cochlear implant surgery before 5 years old. The use of hearing aid contralateral to the cochlear implant had a significant influence on the participants performances on tests. The participants who started using hearing aids earlier did not have the best results on the tests.

Conclusion:

the early activation of the cochlear implant is an important variable on the tests performance. The use of hearing aid contralateral to the cochlear implant had a significant influence on the speech recognition tests.


Full text: Available Index: LILACS (Americas) Language: Portuguese Journal: Rev. CEFAC Journal subject: Terapia / Speech-Language Pathology / Terapia / Reabilita‡Æo Year: 2014 Type: Article Affiliation country: Brazil Institution/Affiliation country: Centro Educacional da Audição e Linguagem ? Ludovico Pavoni/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Language: Portuguese Journal: Rev. CEFAC Journal subject: Terapia / Speech-Language Pathology / Terapia / Reabilita‡Æo Year: 2014 Type: Article Affiliation country: Brazil Institution/Affiliation country: Centro Educacional da Audição e Linguagem ? Ludovico Pavoni/BR