Your browser doesn't support javascript.
loading
Proposta de correção virtual geométrica da projeção ostial da artéria renal no estudo operatório de aneurismas infrarrenais: resultados iniciais de um estudo piloto / Proposal of renal artery's ostial projection under virtual geometric correction in infrarenal aneurysms: initial results of a pilot study
Molinari, Giovani José Dal Poggetto; Dalbem, Andreia Marques de Oliveira; Menezes, Fabio Hüsemann; Guillaumon, Ana Terezinha.
  • Molinari, Giovani José Dal Poggetto; Universidade Estadual de Campinas. Campinas. BR
  • Dalbem, Andreia Marques de Oliveira; Universidade Estadual de Campinas. Campinas. BR
  • Menezes, Fabio Hüsemann; Universidade Estadual de Campinas. Campinas. BR
  • Guillaumon, Ana Terezinha; Universidade Estadual de Campinas. Campinas. BR
Rev. bras. cir. cardiovasc ; 29(1): 78-82, Jan-Mar/2014. tab, graf
Article in Portuguese | LILACS | ID: lil-710088
RESUMO

Introdução:

Para o preparo pré-operatório endovascular dos aneurismas infrarrenais é necessária a mensuração acurada de suas características anatômicas e morfológicas, alcançada com o uso de softwares avançados em manipulação de imagens de tomografias multicanais. Este processo permite também o estudo acurado das relações anatômicas das demais artérias do eixo aorto-ilíaco. Uma visualização perpendicular à origem da artéria renal mais baixa possibilita o uso de toda a extensão do colo para fixação da endoprótese e selamento proximal, o que pode ser previsto durante o estudo da tomografia, impedindo um posicionamento subótimo e a sobreposição das estruturas vasculares no intraoperatório. Expõem-se aqui os resultados iniciais de um projeto piloto, envolvendo manipulação de imagens tomográficas, na correção ortogonal da artéria renal aplicada à orientação radioscópica no intraoperatório.

Métodos:

Por meio de reconstrução multiplanar de imagens tomográficas em software obtém-se um corte axial em ângulo reto. Conceitos geométricos de triangulação virtual promovem a correção ortogonal em três dimensões da visualização ostial da artéria renal, que pode ser reproduzida intraoperatoriamente, através do reposicionamento do arco cirúrgico. Resultados/Discussão Embora alguns autores argumentem que a anatomia do vaso observada na tomografia possa mudar durante o intraoperatório, sabe-se que o posicionamento angular das artérias renais não se modifica, mesmo após a inserção dos fios guia rígidos, introdutores e da própria endoprótese. Assim, acreditamos ser possível, por meio de ...
ABSTRACT

Introduction:

Endovascular aneurysm repair requires the precise deployment of the graft. In order to achieve accurate positioning, the anatomical and morphological characteristics of the aorta and its branches is mandatory. Software that perform three dimensional reformatting of multislice tomographic images, allow for the study of the whole aorto-iliac axis and the perpendicular visualization of the origin of the renal arteries. The correct length of the proximal neck can be evaluated and adequate graft fixation and sealing may be foreseen. A technique is presented, using an software, for the orthogonal correction of the position of the renal arteries in relation to the proximal neck, which may guide the radioscopic orientation intraoperatively.

Methods:

Within a multiplanar tomographic image reconstruction, virtual triangulation allows for the three dimensional orthogonal correction of the renal arteries' ostia position. The predetermined best angulations for visualization are annotated and used for the positioning of the surgical C-arm. Results/

Discussion:

Some authors discuss that the anatomic position of the renal vessels seen on the tomographic scan can change during the surgical procedure. It is known that the renal arterys' angular positioning does not alter, even after insertion of stiff guidewires, introducers, and the endograft itself. Therefore, it is possible, using concepts of spacial geometry and orthogonal correction, to predict the ideal bidimensional intraoperative positioning of the radioscopy device in order to reproduce the optimized renal artery ostial projection, ensuring the best accuracy during endograft deployment.

Conclusion:

As closer to the tomographic reproduction was the radioscopic correction, more careful is the visualization of the ostium of the renal artery, better is the exploitation of the lap for fixing and sealing and the endoprosthesis deployment is more accurate. .
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Renal Artery / Software / Tomography, X-Ray Computed / Aortic Aneurysm, Abdominal Type of study: Prognostic study / Qualitative research Limits: Humans Language: Portuguese Journal: Rev. bras. cir. cardiovasc Journal subject: Cardiology / General Surgery Year: 2014 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Estadual de Campinas/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Renal Artery / Software / Tomography, X-Ray Computed / Aortic Aneurysm, Abdominal Type of study: Prognostic study / Qualitative research Limits: Humans Language: Portuguese Journal: Rev. bras. cir. cardiovasc Journal subject: Cardiology / General Surgery Year: 2014 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Estadual de Campinas/BR