Your browser doesn't support javascript.
loading
Effects of calcium hydroxide addition on the physical and chemical properties of a calcium silicate-based sealer
KUGA, Milton Carlos; DUARTE, Marco Antonio Hungaro; SANT'ANNA-JÚNIOR, Arnaldo; KEINE, Kátia Cristina; FARIA, Gisele; DANTAS, Andrea Abi Rached; GUIOTTI, Flávia Angélica.
  • KUGA, Milton Carlos; Univ. Estadual Paulista. Araraquara Dental School. Department of Restorative Dentistry. Araraquara. BR
  • DUARTE, Marco Antonio Hungaro; Univ. Estadual Paulista. Araraquara Dental School. Department of Restorative Dentistry. Araraquara. BR
  • SANT'ANNA-JÚNIOR, Arnaldo; Univ. Estadual Paulista. Araraquara Dental School. Department of Restorative Dentistry. Araraquara. BR
  • KEINE, Kátia Cristina; Univ. Estadual Paulista. Araraquara Dental School. Department of Restorative Dentistry. Araraquara. BR
  • FARIA, Gisele; Univ. Estadual Paulista. Araraquara Dental School. Department of Restorative Dentistry. Araraquara. BR
  • DANTAS, Andrea Abi Rached; Univ. Estadual Paulista. Araraquara Dental School. Department of Restorative Dentistry. Araraquara. BR
  • GUIOTTI, Flávia Angélica; Univ. Estadual Paulista. Araraquara Dental School. Department of Restorative Dentistry. Araraquara. BR
J. appl. oral sci ; 22(3): 180-184, May-Jun/2014. graf
Article in English | LILACS, BBO | ID: lil-711712
ABSTRACT
Recently, various calcium silicate-based sealers have been introduced for use in root canal filling. The MTA Fillapex is one of these sealers, but some of its physicochemical properties are not in accordance with the ISO requirements.

Objective:

The aim of this study was to evaluate the flowability, pH level and calcium release of pure MTA Fillapex (MTAF) or containing 5% (MTAF5) or 10% (MTAF10) calcium hydroxide (CH), in weight, in comparison with AH Plus sealer. Material and

Methods:

The flowability test was performed according to the ISO 68762001 requirements. For the pH level and calcium ion release analyses, the sealers were placed individually (n=10) in plastic tubes and immersed in deionized water. After 24 hours, 7 and 14 days, the water in which each specimen had been immersed was evaluated to determine the pH level changes and calcium released. Flowability, pH level and calcium release data were analyzed statistically by the ANOVA test (α=5%).

Results:

In relation to flowability MTAF>AH Plus>MTAF5>MTAF10. In relation to the pH level, for 24 h MTAF5=MTAF10=MTAF>AH Plus; for 7 and 14 days MTAF5=MTAF10>MTAF>AH Plus. For the calcium release, for all periods MTAF>MTAF5=MTAF10>AH Plus.

Conclusions:

The addition of 5% CH to the MTA Fillapex (in weight) is an alternative to reduce the high flowability presented by the sealer, without interfering in its alkalization potential. .
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Oxides / Root Canal Filling Materials / Calcium Hydroxide / Calcium / Silicates / Calcium Compounds / Aluminum Compounds / Epoxy Resins Type of study: Evaluation studies Language: English Journal: J. appl. oral sci Journal subject: Dentistry Year: 2014 Type: Article Affiliation country: Brazil Institution/Affiliation country: Univ. Estadual Paulista/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Oxides / Root Canal Filling Materials / Calcium Hydroxide / Calcium / Silicates / Calcium Compounds / Aluminum Compounds / Epoxy Resins Type of study: Evaluation studies Language: English Journal: J. appl. oral sci Journal subject: Dentistry Year: 2014 Type: Article Affiliation country: Brazil Institution/Affiliation country: Univ. Estadual Paulista/BR