Your browser doesn't support javascript.
loading
Estudio queratométrico por pentacam en hipermétropes con cirugía láser vs. método de maloney / Keratometric study of hypermetropic patients with laser surgery by using pentacam vs. maloney method
Cárdenas Díaz, Taimí; Vinardell Pérez, Susana; Capote Cabrera, Armando; Pérez Candelaria, Eneida de la C; Cuan Aguilar, Yoriel; Cruz Izquierdo, Dunia.
  • Cárdenas Díaz, Taimí; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Vinardell Pérez, Susana; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Capote Cabrera, Armando; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Pérez Candelaria, Eneida de la C; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Cuan Aguilar, Yoriel; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Cruz Izquierdo, Dunia; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
Rev. cuba. oftalmol ; 27(1): 109-118, ene.-mar. 2014. tab
Article in Spanish | LILACS, CUMED | ID: lil-717240
RESUMEN

OBJETIVO:

comparar las queratometrías obtenidas por el Pentacam en ojos hipermétropes operados por láser y las obtenidas a través del Método de Maloney, en el Instituto Cubano de Oftalmología "Ramón Pando Ferrer", desde marzo a mayo de 2013.

MÉTODOS:

se realizó un estudio prospectivo en 50 ojos de 27 pacientes hipermétropes operados de LASIK, donde se calculó la queratometría promedio mediante el método de Maloney y se comparó con los valores brindados por el Pentacam valor queratométrico total central y Equivalent K- Reading power de los mapas a color, así como el True Net Power (queratométrico total a 3,0 mm) y las lecturas queratométricas a distintos diámetros del programa Holladay Report. Se comparó la queratometría preoperatoria media de la historia clínica y la estimada aportada por el Pentacam. El análisis estadístico se realizó con la prueba T para datos pareados, utilizando una significación del 95 %.

RESULTADOs:

no hubo diferencias estadísticamente significativas entre las queratometrías del método de Maloney, el Equivalent K-reading Power y las lecturas de queratometría efectivas a diferentes diámetros. La de 4,5 mm mostró la menor diferencia. El resto de las mediciones difirieron de forma significativa. No se encontró diferencias entre las queratometrías preoperatorias.

CONCLUSIONES:

el Pentacam aporta poderes corneales que no difieren estadísticamente de los obtenidos por el método de Maloney en ojos hipermétropes con LASIK previo.
ABSTRACT

OBJECTIVE:

to compare the keratometries given by the Pentacam in hyperopic patients operated on with laser and those obtained through Maloney method in "Ramón Pando Ferrer" Cuban Institute of Ophthalmology from March to May of 2013.

METHODS:

a prospective study was conducted in 50 eyes from 27 hyperopic patients operated on with LASIK, in which average keratometry was estimated using Maloney method and then compared with those of Pentacam system; the used variables were total central keratometric value and Equivalent K-reading Power of color maps, as well as the true net power (total keratometic value at 3,0 mm) and the readings of equivalent keratometry at different diameter of HolladayReport programs. The average preoperative keratometries of the medical histories and those of the Pentacam system were also compared. The statistical analysis included paired T test, using a 95 % significance level.

RESULTS:

there were not significant statistical differences among the keratometries by Maloney method, the Equivalent K-reading power and the readings of equivalent keratometries at different diameters, being that of 4,5 mm the more accurate. The rest of the measurements differed in a significant way. There were differences among the preoperative keratometries.

CONCLUSION:

the Pentacam system provides corneal powers that did not statistically differ from those obtained by the Maloney method in hyperopic eyes with prior LASIK.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Cataract Extraction / Corneal Surgery, Laser / Laser Therapy / Hyperopia Type of study: Observational study Limits: Aged / Humans Language: Spanish Journal: Rev. cuba. oftalmol Journal subject: Ophthalmology Year: 2014 Type: Article Affiliation country: Cuba Institution/Affiliation country: Instituto Cubano de Oftalmología Ramón Pando Ferrer/CU

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Cataract Extraction / Corneal Surgery, Laser / Laser Therapy / Hyperopia Type of study: Observational study Limits: Aged / Humans Language: Spanish Journal: Rev. cuba. oftalmol Journal subject: Ophthalmology Year: 2014 Type: Article Affiliation country: Cuba Institution/Affiliation country: Instituto Cubano de Oftalmología Ramón Pando Ferrer/CU