RESUMO
Objetivo caracterizar e comparar a audição de funcionários de um hospital público expostos a níveis de ruído ocupacional máximos superiores e inferiores a 85dB(A). Métodos trata-se de um estudo clínico, com 39 funcionários de um hospital público, divididos de acordo com o nível de exposição ao ruído: 20 indivíduos sob exposição máxima superior a 85dB(A) (Grupo 1) e 19 indivíduos sob exposição máxima inferior a 85dB(A) (Grupo 2). Foi realizada avaliação audiológica básica e emissões otoacústicas evocadas por estímulo transiente e produto de distorção. Resultados ambos os grupos apresentaram limiares de audibilidade normais. Contudo, observou-se ausência de respostas em 87,5% no Grupo 1 e 60,5% no Grupo 2 no teste de emissões otoacústicas evocadas por estímulo transiente, com diferença estatística. O Grupo 1 mostrou menor amplitude de respostas também às emissões otoacústicas produto de distorção, sendo a frequência de 6kHz a única alterada em ambos os grupos. Conclusão os níveis de pressão sonora e o tempo de exposição não influenciam os limiares auditivos tonais. As emissões otoacústicas mostraram-se mais alteradas quanto maior o nível de pressão sonora e tempo de exposição. .
ABSTRACT
Purpose to characterize and to compare the hearing of employees of a public hospital exposed to maximum occupational noise levels above and below 85dB(A). Methods this clinical study selected 39 workers of a public hospital, divided according to the level of noise exposure: 20 subjects with maximum exposure levels above 85dB(A) (Group 1) and 19 individuals with maximum exposure levels below 85dB(A) (Group 2). Basic audiological evaluation, transient and distortion product otoacoustic emissions were carried out. Results both groups presented normal hearing thresholds. However, 87.5% in Group 1 and 60.5% in Group 2 showed absent responses in transient evoked otoacoustic emissions, with statistical difference. Group 2 showed higher signal/noise ratios also in distortion product otoacoustic emissions, and only the frequency of 6 kHz was abnormal in both groups. Conclusion sound pressure levels and noise exposure time did not influence in pure tone thresholds. The higher the sound pressure level and the longer the exposure time, more altered the otoacoustic emissions, indicating cochlear dysfunction. .


Full text: Available Index: LILACS (Americas) Language: Portuguese Journal: Rev. CEFAC Journal subject: Terapia / Speech-Language Pathology / Terapia / Reabilita‡Æo Year: 2014 Type: Article / Project document Affiliation country: Brazil Institution/Affiliation country: Universidade Federal de São Paulo/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Language: Portuguese Journal: Rev. CEFAC Journal subject: Terapia / Speech-Language Pathology / Terapia / Reabilita‡Æo Year: 2014 Type: Article / Project document Affiliation country: Brazil Institution/Affiliation country: Universidade Federal de São Paulo/BR