Your browser doesn't support javascript.
loading
Comparative analysis of the radiopacity of MTA and Portland cement in conventional and digital radiographic systems / Análise Comparativa da Radiopacidade do MTA e Cimento Portland nos Sistemas Radiográficos Digitais e Convencionais
Guimarães, Carolina dos Santos; Sobral, Ana Paula Veras; Pedrosa, Ricardo Ferreira; Silva, Luciano Barreto; Silveira, Márcia Maria Fonseca da.
  • Guimarães, Carolina dos Santos; Faculdade de Odontologia de Pernambuco. Camaragibe. BR
  • Sobral, Ana Paula Veras; Faculdade de Odontologia de Pernambuco. Camaragibe. BR
  • Pedrosa, Ricardo Ferreira; Faculdade de Odontologia de Pernambuco. Camaragibe. BR
  • Silva, Luciano Barreto; Faculdade de Odontologia de Pernambuco. Camaragibe. BR
  • Silveira, Márcia Maria Fonseca da; Faculdade de Odontologia de Pernambuco. Camaragibe. BR
Rev. Fac. Odontol. Porto Alegre ; 51(3): 11-15, set.-dez. 2010. ilus
Article in English | LILACS, BBO | ID: lil-719574
RESUMO

Objetivo:

O presente estudo teve como objetivo avaliar a radiopacidade do Agregado de trióxido mineral (MTA) e Cimento Portland (PC) em imagens radiográficas convencionais e digitais a fim de verificar se estão em conformidade com a especificação ANSI / ADA.

Materiais e Métodos:

Cinco corpos de prova para cada material com 10mm de diâmetro, 1mm de espessura e um penetrômetro foram expostos a 70kVp, 8mA a uma distância foco-filme de 30cm. Os tempos de exposição foram 0,4 e 0,2 s para o filme Insight Kodak e sistema digital CR Kodak 7400, respectivamente. A densidade óptica foi medida na radiografia através de um fotodensitômetro e o valor de pixel foi obtido para as imagens digitais. Um gráfico dos valores obtidos versus mmAl foi elaborado a fim de gerar uma curva de radiopacidade dos degraus do penetrômetro, obtendo a correspondência em equivalência de mmAl dos materiais estudadosUm gráfico foi feito para os valores medidos em comparação mmAl, a fim de gerar uma curva de radiopacidade dos passos penetrômetro, obtendo-se a correspondência de equivalência de mmAl dos materiais estudados.

Resultados:

O teste estatístico de Mann-Whitney mostrou diferença estatística significativa na radiopacidade entre MTA e PC, tanto no sistema convencional (valor p = 0,009) e digital(valor p = 0,009). O mesmo teste também mostrou diferença estatística significativa entre os sistemas convencionais e digitais em ambos os materiais (p = 0,016 valueMTA-e p-valuecp = 0,009).

Conclusões:

MTA e CP não apresentaram radiopacidade dentro dos padrões exigidos pela especificação N ○ 57 do American National Standards / American Dental Association.
ABSTRACT

Objective:

The present study aimed to evaluate the radiopacity of Mineral Trioxide Aggregate (MTA) and Portland Cement (PC) in conventional and digital radiographic images in order to verify if they are in accordance with ANSI/ADA specification. Materials and

Methods:

For each material five test specimens with 10mm of diameter, 1mm of thickness and a stepwedge were exposed at 70kVp, 8mA and focal distance of 30cm. Exposure times were 0,4 and 0,2s for Kodak Insight film and Kodak CR 7400 digital system, respectively. The optic density was measured in the radiograph using a photo-densitometer and the value of pixel was obtained for digital images. A graph was made for measured values versus mmAl in order to generate a radiopacity curve of the stepwedge steps, obtaining the correspondence in equivalence of mmAl of the studied materials.

Results:

The statistical Mann-Whitney test showed statistical significant difference in the radiopacity between MTA and PC in both conventional (p value = 0,009) and digital (p value = 0,009) systems. The same test also showed statistical significant difference between conventional and digital systems in both materials (p-valueMTA=0,016 and p-valuecp = 0,009).

Conclusions:

MTA and CP did not show radiopacity inside of the standards demanded by specification N○ 57 of the American National Standards/ American Dental Association.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Root Canal Filling Materials / Radiography, Dental / Radiography, Dental, Digital / Dental Cements / Dental Materials Language: English Journal: Rev. Fac. Odontol. Porto Alegre Journal subject: Dentistry Year: 2010 Type: Article Affiliation country: Brazil Institution/Affiliation country: Faculdade de Odontologia de Pernambuco/BR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Root Canal Filling Materials / Radiography, Dental / Radiography, Dental, Digital / Dental Cements / Dental Materials Language: English Journal: Rev. Fac. Odontol. Porto Alegre Journal subject: Dentistry Year: 2010 Type: Article Affiliation country: Brazil Institution/Affiliation country: Faculdade de Odontologia de Pernambuco/BR