Your browser doesn't support javascript.
loading
Intervalos de referência para o volume da cisterna magna fetal por meio do método bidimensional usando o modo multiplanar da ultrassonografia tridimensional / Reference intervals of fetal cisterna magna volume by two-dimensional method using the multiplanar mode of three-dimensional ultrasonography
Nardozza, Luciano Marcondes Machado; Passos, Ana Paula; Araujo Júnior, Edward; Bruns, Rafael Frederico; Moron, Antonio Fernandes.
  • Nardozza, Luciano Marcondes Machado; Universidade Federal de São Paulo. Escola Paulista de Medicina. Departamento de Obstetrícia. São Paulo. BR
  • Passos, Ana Paula; Universidade Federal de São Paulo. Escola Paulista de Medicina. Departamento de Obstetrícia. São Paulo. BR
  • Araujo Júnior, Edward; Universidade Federal de São Paulo. Escola Paulista de Medicina. Departamento de Obstetrícia. São Paulo. BR
  • Bruns, Rafael Frederico; Universidade Federal de São Paulo. Escola Paulista de Medicina. Departamento de Obstetrícia. São Paulo. BR
  • Moron, Antonio Fernandes; Universidade Federal de São Paulo. Escola Paulista de Medicina. Departamento de Obstetrícia. São Paulo. BR
Radiol. bras ; 47(4): 201-205, Jul-Aug/2014. tab, graf
Article in Portuguese | LILACS | ID: lil-720942
RESUMO

Objetivo:

Determinar intervalos de referência para o volume da cisterna magna fetal por meio do método bidimensional (2D) usando o modo multiplanar da ultrassonografia tridimensional.

Materiais e Métodos:

Estudo de corte transversal com 224 gestantes normais entre a 17ª e 29ª semanas. O volume foi obtido automaticamente pela multiplicação dos três maiores eixos nos planos axial e sagital pela constante 0,52. Regressão polinomial foi realizada para obter correlação entre o volume 2D da cisterna magna e a idade gestacional, sendo os ajustes realizados pelo coeficiente de determinação (R2). Confiabilidade e concordância foram obtidas pelo coeficiente de correlação intraclasse (CCI) e limites de concordância.

Resultados:

A média do volume da cisterna magna 2D variou de 0,71 ± 0,19 cm3 para 4,18 ± 0,75 cm3 entre a 17ª e 29ª semanas, respectivamente. Observou-se boa correlação do volume da cisterna magna fetal 2D e a idade gestacional (R2 = 0,67). Observou-se excelente confiabilidade e concordância intraobservador com CCI = 0,89 e limites de concordância 95% (-52,0; 51,8), respectivamente. Observou-se baixa confiabilidade e concordância interobservador com CCI = 0,64 e limites de concordância 95% (-110,1; 84,6), respectivamente.

Conclusão:

Intervalos de referência para o volume 2D da cisterna magna fetal usando o modo multiplanar da ultrassonografia tridimensional foram determinados e apresentaram excelente confiabilidade e concordância intraobservador. .
ABSTRACT

Objective:

To establish reference intervals for the fetal cisterna magna volume by means of two-dimensional (2D) method using the multiplanar mode of three-dimensional ultrasonography. Materials and

Methods:

Cross-sectional study with 224 healthy pregnant women between the 17th and 29th gestational weeks. The volume was automatically obtained by multiplying the three major axes in axial and sagittal planes by the constant 0.52. Polynomial regression was utilized to establish the correlation between fetal cisterna magna volume and gestational age, with adjustments by coefficient of determination (R2). Reliability and agreement were obtained by intraclass correlation coefficient (ICC) and limits of agreement, respectively.

Results:

Mean fetal cisterna volume with the 2D method ranged from 0.71 ± 0.19 cm3 to 4.18 ± 0.75 cm3 at the 17th and 29th weeks, respectively. The authors observed a good correlation between fetal cisterna magna volume and gestational age (R2 = 0.67), excellent intraobserver reliability and agreement with ICC = 0.89 and limits of agreement 95% (-52.0; 51.8), respectively, and low interobserver reliability and agreement with ICC = 0.64 and limits of agreement 95% (-110.1; 84.6), respectively.

Conclusion:

Reference intervals for fetal cisterna magna volume by means of 2D method using the multiplanar mode of three-dimensional ultrasonography were established and presented excellent intraobserver reliability and agreement. .


Full text: Available Index: LILACS (Americas) Type of study: Observational study / Prevalence study Language: Portuguese Journal: Radiol. bras Journal subject: Diagnostic Imaging / Radiology Year: 2014 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal de São Paulo/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Type of study: Observational study / Prevalence study Language: Portuguese Journal: Radiol. bras Journal subject: Diagnostic Imaging / Radiology Year: 2014 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal de São Paulo/BR