Eletromiográfia do reto femoral em diferentes equipamentos proprioceptivos no meio aquático / Eletromyography of the rectus femoris in different proprioceptive devices in a hydrotherapy pool / Electromiografía del recto femoral en diferentes equipamientos propioceptivos en el medio acuático
Martins, Cassio Noronha; Tarouco, Cassius Porciuncula; Martin, Daniela Gomez; Signori, Luis Ulisses.
  • Martins, Cassio Noronha; Universidade Federal do Rio Grande. Rio Grande. BR
  • Tarouco, Cassius Porciuncula; Universidade Federal do Rio Grande. Rio Grande. BR
  • Martin, Daniela Gomez; Universidade Federal do Rio Grande. Rio Grande. BR
  • Signori, Luis Ulisses; Universidade Federal do Rio Grande. Rio Grande. BR
Rev. bras. med. esporte ; 20(4): 289-293, July-Aug/2014. graf
Article in Portuguese | LILACS | ID: lil-720971
RESUMO

INTRODUÇÃO:

A propriocepção é uma variável imprescindível para prevenção e reabilitação das lesões do joelho, podendo ser estimulada por diferentes equipamentos, os quais ainda não foram testados em meio aquático.

OBJETIVO:

Avaliar a atividade eletromiográfica (EMG) do músculo reto femoral de atletas no meio aquático frente a três diferentes equipamentos proprioceptivos (cama elástica, disco proprioceptivo e balancim).

MÉTODOS:

A amostra foi composta por dez jogadores de futsal profissional, sem histórico de lesões musculoesqueléticas (últimos três meses), com 23,1 (±1,5) anos e índice de massa corporal 25,2 (±0,5) kg/m². A aquisição do sinal EMG do reto femoral do membro dominante foi adquirido por eletrodos de superfície, aproximadamente 2,5 cm da posição distal do ponto motor. O nível da água foi ajustado individualmente (entre a região umbilical e o processo xifoide) e a temperatura mantida a 32 °C. As avaliações compreenderam o repouso, a contração voluntária máxima (CVM) antes e depois dos experimentos e os estímulos proprioceptivos (cama elástica, disco proprioceptivo e balancim) em apoio unipodal. Os dados (média ± erro padrão) foram comparados pelo teste-t pareado e pela ANOVA para medidas repetidas seguida de teste Bonferrroni (post hoc).

RESULTADOS:

A EMG da CVM antes (221,0 ± 134 RMS/µVolts) e depois (243,0 ± 154,0 RMS/µVolts) foi semelhante (p = 0,129). No meio aquático, a cama elástica, o balancim e o disco apresentaram respectivamente 24,5 (±4,3), 33,9 (±4,3) e 32,5 (±6,7) %CVM. A atividade EMG do reto femoral na cama elástica foi 8% menor que o balancim e 9,5% que o disco proprioceptivo (p < 0,001).

CONCLUSÃO:

...
ABSTRACT

INTRODUCTION:

Proprioception is an essential variable for prevention and rehabilitation of knee injuries and can be stimulated by different equipment, which have not yet been tested in water.

OBJECTIVE:

To evaluate the electromyographic (EMG) activity of the rectus femoris muscle of athletes in aquatic environment using three different proprioceptive equipment (trampoline, balance disc and rocker board).

METHODS:

The sample comprised ten professional futsal players with no history of musculoskeletal injuries (last three months), with 23.1 (±1.5) years old and body mass index of 25.2 (±0.5) kg/m². The EMG of the rectus femoris of the dominant member was acquired by placing surface electrodes approximately 2.5cm from the distal position of the motor point. The water level was individually adjusted (between the umbilical region and the xiphoid process) and the temperature was maintained at 32ºC. The evaluations included rest, maximum voluntary contraction (MVC) before and after the experiments and proprioceptive stimuli (trampoline, balance disc and rocker board) in one leg. The data (mean ± standard error) were compared by paired t-test and ANOVA for repeated measures followed by Bonferroni post-hoc test.

RESULTS:

The EMG of MVC before (221.0 ± 134 RMS/µVolts) and after (243.0 ± 154.0 RMS/µVolts) were similar (p=0.129). In the aquatic environment, the trampoline, the rocker board and the balance disc showed respectively 24.5 (±4.3), 33.9 (±4.3) and 32.5 (±6.7) %CVM. The EMG activity of the rectus femoris muscle in the trampoline was 8% lower than the rocker board and 9.5% than the balance disc (p<0.001).

CONCLUSION:

In the aquatic environment proprioceptive equipment promote the activation of the rectus femoris muscle. However, the trampoline has lower activity than the disc and the rocker board, suggesting that this equipment should be employed at the beginning ...
RESUMEN

INTRODUCCIÓN:

La propiocepción es una variable imprescindible para prevención y rehabilitación de las lesiones de la rodilla, pudiendo ser estimulada por diferentes equipamientos, los que aún no fueron probados en medio acuático.

OBJETIVO:

Evaluar la actividad electromiográfica (EMG) del músculo recto femoral de atletas en el medio acuático frente a tres diferentes equipamientos propioceptivos (cama elástica, disco propioceptivo y balancín).

MÉTODOS:

La muestra fue compuesta por diez jugadores de futsal profesional, sin historial de lesiones musculoesqueléticas (últimos tres meses), con 23,1 (±1,5) años e índice de masa corporal 25,2 (±0,5) kg/m². La adquisición de la señal EMG del recto femoral del miembro dominante fue adquirida por electrodos de superficie, aproximadamente 2,5 cm de la posición distal del punto motor. El nivel del agua fue ajustado individualmente (entre la región umbilical y el proceso xifoide) y la temperatura mantenida a 32 °C. Las evaluaciones comprendieron el reposo, la contracción voluntaria máxima (CVM) antes y después de los experimentos y los estímulos propioceptivos (cama elástica, disco propioceptivo y balancín) en apoyo unipodal. Los datos (promedio ± error estándar) fueron comparados por el test-t apareado y por ANOVA para medidas repetidas seguida de test Bonferrroni (post hoc).

RESULTADOS:

La EMG de la CVM antes (221,0 ± 134 RMS/µVolts) y después (243,0 ± 154,0 RMS/µVolts) fueron semejantes (p = 0,129). En el medio acuático, la cama elástica, el balancín y el disco presentaron respectivamente 24,5 (±4,3), 33,9 (±4,3) y 32,5 (±6,7) %CVM. La actividad EMG del recto femoral en la cama elástica fue 8% menor que el balancín y 9,5% que el disco propioceptivo (p < 0,001). ...