Your browser doesn't support javascript.
loading
O uso do centro articular do quadril e do centro de gravidade da cabeça como referência na estimativa de parâmetros cinemáticos da performance em corridas de velocidade / The use of the hip joint center and head gravity center as a reference to estimate the performance kinematics parameters in speed races
Pupo, Juliano Dal; Teixeira, Clarissa Stefani; Rocha Júnior, Ivon Chagas; Mota, Carlos Bolli.
  • Pupo, Juliano Dal; Universidade Federal de Santa Catarina. Florianópolis. BR
  • Teixeira, Clarissa Stefani; Universidade Federal de Santa Catarina. Florianópolis. BR
  • Rocha Júnior, Ivon Chagas; Universidade Federal de Santa Maria. Santa Maria. BR
  • Mota, Carlos Bolli; Universidade Federal de Santa Maria. Santa Maria. BR
Rev. bras. ciênc. mov ; 17(4): 10-17, jan.-mar. 2009. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-727843
RESUMO
O objetivo deste estudo foi comparar a velocidade e o deslocamento do centro de gravidade global (CGG) com as centro de gravidade da cabeça (CGC) e do centro articular do quadril (CAQ), durante um passo em corridas de velocidade. A partir disso, determinar se tais pontos podem ser utilizados como indicadores de parâmetros da performance nos estudos envolvendo a cinemática das corridas. Participaram deste estudo 8 sujeitos do sexo masculino, com idade média de 12,5 ± 0,66 anos e estatura média de 163,00 ± 5,40 cm. Realizou-se uma análise cinemática da corrida, utilizando-se o método de videografia tridimensional, com quatro câmeras de vídeo do sistema de análise do movimento Peak Motus, operando na freqüência de 180 Hz. As variáveis analisadas foram deslocamento, velocidade média e velocidade instantânea horizontal do CGG, CGC e CAQ referentes a um passo. Os resultados encontrados mostraram não haver diferenças significativas na velocidade média e amplitude de deslocamento entre os três pontos analisados. Em relação à velocidade instantânea analisada em todo passo, não verificou-se diferenças significativas, porém, as variações na curva de velocidade do CAQ não ocorreram na mesma escala de tempo quando comparado com os demais pontos. Concluiu-se assim que, tanto o CGG, assim como o CGC e CAQ, podem ser utilizados para descrever parâmetros cinemáticos da corrida, quando o objetivo da análise referir-se a deslocamentos e velocidade média de um passo. Em relação à descrição da velocidade instantânea do atleta nas diferentes fases do passo, o uso do CGG e CGC parecem ser os mais adequados a serem utilizados.
ABSTRACT
The objective of this study was to compare the speed and the displacement of the global gravity center (CGG) with the head gravity center (CGC) and the hip joint center (CAQ) during a step in speed races. After, to determine if these points could be used as indicators of the performance parameters in the studies involving the kinematics of the speed races. To accomplish this study, eight male subjects participated. They were around 12.5 ± 0.66 years old and their average height was 163.00 ± 5.40 cm. A kinematic analysis of the running was carried out by using the method of three-dimensional videography, with four video cameras of the Peak Motus system operating in the frequency of 180 Hz. The analyzed variables were displacement, average speed and horizontal instantaneous speed of CGG, CGC and CAQ that refer to one step. The results showed that there are not significant statistical differences in both the average speed and the displacement amplitude among the three analyzed points. Concerning the instantaneous speed analyzed in the whole step, no significant differences were found. However, the variations in the CAQ speed curve did not occur in the same scale of time when compared with the other points. Thus, one concluded that the CGG, the CGC and the CAQ can be used to describe kinematics parameters of the running when the aim of analysis refers to displacement and average speed of one step. Concerning the description of instantaneous speed of athletes in different step phases, the use of CGG and CGC seems to be the most appropriate.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Running / Outflow Velocity Measurement / Athletes Limits: Adult / Humans / Male Language: Portuguese Journal: Rev. bras. ciênc. mov Journal subject: Sports Medicine Year: 2009 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal de Santa Catarina/BR / Universidade Federal de Santa Maria/BR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Running / Outflow Velocity Measurement / Athletes Limits: Adult / Humans / Male Language: Portuguese Journal: Rev. bras. ciênc. mov Journal subject: Sports Medicine Year: 2009 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal de Santa Catarina/BR / Universidade Federal de Santa Maria/BR