RESUMEN

Introducción:

el estudio de repetibilidad y reproducibilidad se basa en la cuantificación experimental de la contribución del sistema de medición a la variabilidad total observada, y determina si este es aceptable o no.

Objetivo:

evaluar el sistema de medición en la fabricación de gel de hidróxido de aluminio mediante el estudio de repetibilidad y reproducibilidad.

Métodos:

el estudio de repetibilidad y reproducibilidad se desarrolló a través de un experimento factorial balanceado de efecto aleatorio. Se tomaron 10 muestras (partes) del producto terminado, de un lote de producción, las que se midieron dos veces por tres operadores seleccionados aleatoriamente. Las mediciones se realizaron en el Laboratorio de Investigación de Medilip (nivel de confianza α= 0,05; 95 por ciento). Se aplicó el método ANOVA cruzado. El procesamiento de los datos se realizó utilizando el paquete estadístico Minitab 16.

Resultados:

según los índices Cg y Cgk (estudio tipo I), se comprobó que el sistema de medición fue aceptable. Con el estudio de repetibilidad y reproducibilidad se determinó que el factor que contribuye en mayor cuantía resultó el denominado partes (96,85 por ciento) y que la contribución de la variabilidad del sistema de medición (3,15 por ciento) fue aceptable, así como el porcentaje de la varianza del estudio con respecto a la varianza total (17,75 por ciento).

Conclusiones:

el estudio de repetibilidad y reproducibilidad identifica al factor parte como el de mayor contribución a la variabilidad total y que el sistema de medición es adecuado, lo cual está avalado por los índices reconocidos internacionalmente, por lo que se recomenda tomar acciones para mejorar el desempeño(AU)
ABSTRACT

Introduction:

the repeatability and reproducibility study is based on experimental quantitation of the measurement system contribution to the total observed variability, and is aimed at determining whether this system is acceptable.

Objective:

to evaluate the measurement system in aluminum hydroxide gel production process through the repeatability and reproducibility study.

Methods:

this study was carried out through a balanced factorial experiment of random effect. Ten finished product samples from a production batch were measured twice by three randomly selected operators. The measurements were made in the Medilip research laboratory (Cross ANOVA method. Confidence level α= 0.05; 95 percent). The statistical package Minitab 16 served to process relevant data.

Results:

according to Cg and Cgk (type I Study) indexes, the measurement system was acceptable. The repeatability and reproducibility study determined that the main contributing factor was parts (98.85 percent) and that the measurement system variability (3.15) was also allowable as well as the percentage of the study variance with regard to the total variance (17.75 percent).

Conclusions:

the repeatability and reproducibility study identifies the factor called parts as the one largely contributing to the total variability and determines that the measurement system is adequate, which is endorsed by international set standards, so it is recommended to take actions to improve its performance(AU)
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Aluminum Hydroxide Type of study: Controlled clinical trial / Prognostic study Limits: Female / Humans / Male Language: Spanish Journal: Rev. cuba. farm Journal subject: Pharmacy Year: 2014 Type: Article Affiliation country: Cuba / Ecuador Institution/Affiliation country: Universidad Técnica de Cotopaxi/EC / Universidad de Granma/CU

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Aluminum Hydroxide Type of study: Controlled clinical trial / Prognostic study Limits: Female / Humans / Male Language: Spanish Journal: Rev. cuba. farm Journal subject: Pharmacy Year: 2014 Type: Article Affiliation country: Cuba / Ecuador Institution/Affiliation country: Universidad Técnica de Cotopaxi/EC / Universidad de Granma/CU