Your browser doesn't support javascript.
loading
Modelo mecanobiológico de una tibia humana para determinar su respuesta ante estímulos mecánicos externos / Mechanobiological model of a human tibia to determine its response to external mechanical stimuli
Cisneros Hidalgo, Yosbel Angel; Alfonso González Carbonell, Raide; Ortiz Prado, Armando; Jacobo Almendáriz, Victor Hugo; Puente Álvarez, Antonio.
  • Cisneros Hidalgo, Yosbel Angel; Facultad de Electromecánica. Universidad de Camagüey. Camagüey. CU
  • Alfonso González Carbonell, Raide; Facultad de Electromecánica. Universidad de Camagüey. Camagüey. CU
  • Ortiz Prado, Armando; Facultad de Electromecánica. Universidad de Camagüey. Camagüey. CU
  • Jacobo Almendáriz, Victor Hugo; Facultad de Electromecánica. Universidad de Camagüey. Camagüey. CU
  • Puente Álvarez, Antonio; Facultad de Electromecánica. Universidad de Camagüey. Camagüey. CU
Rev. cuba. invest. bioméd ; 34(1): 54-63, ene.-mar. 2015. ilus
Article in Spanish | LILACS, CUMED | ID: lil-752981
RESUMEN

INTRODUCCIÓN:

las nuevas herramientas informáticas cada vez más influyen en los avances científicos tecnológicos en la esfera de la salud. Una de las áreas de mayor implementación de estas nuevas herramientas de cómputo es sin dudas, la ortopedia, debido en lo fundamental, a la similitud que tiene el cuerpo humano y su estructura ósea con las propiedades de los materiales de ingeniería que permite modelar tejidos y órganos en correspondencia con teorías remodeladoras que predicen su posible comportamiento mecanobiológico.

OBJETIVO:

describir el comportamiento de una tibia humana ante estímulos externos de torsión.

MÉTODOS:

se utilizó el Método de los Elementos Finitos implementado en el software profesional ABAQUS/CAE para el cálculo de tensiones y deformaciones presentes en la tibia humana.

RESULTADOS:

se obtuvo el modelo específico del paciente con síndrome de torsión tibial, a partir de las imágenes médicas de un tomógrafo; las cuales fueron procesadas por ordenador, se utiliza el software de tratamiento de imágenes médicas MIMICS 10.01 para establecer una relación entre la escala de grises (unidades Hounsfield), la densidad ósea y el módulo de Young.

CONCLUSIONES:

se determinó que el valor correcto de momento torsor estático que debe ser aplicado a este paciente para iniciar el proceso remodelador es de 30 Nm.
ABSTRACT

INTRODUCTION:

new information tools have a growing influence on technological and scientific advances in health care. Orthopedics is one of the areas where new computational tools have been largely implemented, mainly owing to the similarity of the human body and its bone structure to the properties of engineering materials, enabling the modeling of tissues and organs in accordance with remodeling theories predicting their potential mechanobiological behavior.

OBJECTIVE:

describe the response of a human tibia to external torsion stimuli.

METHODS:

estimation of tensions and deformities in the human tibia was based on the Finite Element Method incorporated into the professional software Abaqus / CAE.

RESULTS:

starting from medical tomographic images, a specific model was obtained for a patient with tibial torsion syndrome. The images were computer processed with the medical imaging treatment software MIMICS 10.01 to establish a relationship between the grayscale (Hounsfield units), bone density and Young's modulus.

CONCLUSIONS:

it was determined that 30 Nm is the correct static torsion moment value to be applied to this patient to start the remodeling process.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Tibia / Computational Biology / Finite Element Analysis Type of study: Prognostic study Limits: Humans Language: Spanish Journal: Rev. cuba. invest. bioméd Journal subject: Medicine Year: 2015 Type: Article Affiliation country: Cuba Institution/Affiliation country: Facultad de Electromecánica/CU

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Tibia / Computational Biology / Finite Element Analysis Type of study: Prognostic study Limits: Humans Language: Spanish Journal: Rev. cuba. invest. bioméd Journal subject: Medicine Year: 2015 Type: Article Affiliation country: Cuba Institution/Affiliation country: Facultad de Electromecánica/CU