Your browser doesn't support javascript.
loading
Decúbito lateral para tratamento das fraturas pertrocantéricas com hastes cefalomedulares / Lateral decubitus for treating pertrochanteric fractures using cephalomedullary nails
Oliveira, Elton João Nunes de; Hungria, José Octávio Soares; Bellan, Davi Gabriel; Borracini, Jonas Aparecido.
  • Oliveira, Elton João Nunes de; Hospital Municipal Dr. Fernando Mauro Pires da Rocha. BR
  • Hungria, José Octávio Soares; Hospital Municipal Dr. Fernando Mauro Pires da Rocha. BR
  • Bellan, Davi Gabriel; Hospital Municipal Dr. Fernando Mauro Pires da Rocha. BR
  • Borracini, Jonas Aparecido; Hospital Municipal Dr. Fernando Mauro Pires da Rocha. BR
Rev. bras. ortop ; 50(4): 409-415, July-Aug. 2015. tab, ilus
Article in English | LILACS | ID: lil-761122
RESUMO
Fazer uma avaliação radiográfica retrospectiva da redução e posição do implante na cabeça femoral em pacientes com fraturas pertrocantéricas tratados com haste cefalomedular em decúbito lateral e fatores que possam interferir na qualidade da redução da fratura e posição do implante no uso dessa técnica.

MÉTODOS:

Foram avaliados retrospectivamente 19 pacientes com diagnóstico de fratura pertrocantérica do fêmur tratados com haste cefalomedular em decúbito lateral. Para avaliação radiográfica ambulatorial usamos as incidências anteroposterior da pelve e o perfil do lado afetado. Aferimos o ângulo cervicodiafisário, o TAD, a posição espacial do elemento cefáfilo em relação à cabeça e o diâmetro biespinhal. Para avaliação antropométrica usamos índice de massa corporal. Foram criados dois grupos de pacientes, um com todos os critérios normais (TAD < 25 mm, ângulo cervicodiafisário entre 130° e 135° e a posição do implante cefálico na cabeça femoral no quadrante central-central) e outro com alteração em algum dos critérios de melhor prognóstico.

RESULTADOS:

Houve predomínio do sexo feminino (57,9%), com idade média de 60 anos. Sete pacientes ficaram com a posição do implante cefálico na posição central-central, um apresentou ângulo cervicodiafisário > 135° e o TAD máximo foi de 32 mm. Consequentemente, 12 pacientes apresentaram algum dos critérios alterados (63,2%). Nenhuma das características avaliadas diferiu ou mostrou associação estatisticamente significativa entre pacientes com todos os critérios normais e algum critério alterado (p > 0,05).

CONCLUSÃO:

A técnica descrita permite uma boa redução e um bom posicionamento do implante, independentemente dos índices antropométricos e do tipo de fratura.
ABSTRACT
To perform a retrospective radiographic evaluation on the fracture reduction and implant position in the femoral head among patients with pertrochanteric fractures who had been treated using a cephalomedullary nail in lateral decubitus; and to assess factors that might interfere with the quality of the fracture reduction and with the implant position in using this technique.

METHODS:

Nineteen patients with a diagnosis of pertrochanteric fractures of the femur who had been treated using cephalomedullary nails in lateral decubitus were evaluated. For outpatient radiographic evaluations, we used the anteroposterior view of the pelvis and lateral view of the side affected. We measured the cervicodiaphyseal angle, tip-apex distance (TAD), spatial position of the cephalic element in relation to the head, and the bispinal diameter. To make an anthropometric assessment, we used the body mass index. Two groups of patients were created one in which all the criteria were normal (TAD ≤25 mm, cervicodiaphyseal angle between 130° and 135° and cephalic implant position in the femoral head in the central-central quadrant); and another group presenting alterations in some of the criteria for best prognosis.

RESULTS:

Female patients predominated (57.9%) and the mean age was 60 years. Seven patients presented a central-central cephalic implant position. One patient present a cervicodiaphyseal angle >135° and the maximum TAD was 32 mm; consequently, 12 patients presented some altered criteria (63.2%). None of the characteristics evaluated differed between the patients with all their criteria normal and those with some altered criteria, or showed any statistically significant association among them ( p> 0.05).

CONCLUSION:

The technique described here enabled good reduction and good positioning of the implant, independent of the anthropometric indices and type of fracture.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Femoral Fractures / Hip Fractures Type of study: Prognostic study Limits: Female / Humans / Male Language: English Journal: Rev. bras. ortop Journal subject: Orthopedics Year: 2015 Type: Article Affiliation country: Brazil Institution/Affiliation country: Hospital Municipal Dr. Fernando Mauro Pires da Rocha/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Femoral Fractures / Hip Fractures Type of study: Prognostic study Limits: Female / Humans / Male Language: English Journal: Rev. bras. ortop Journal subject: Orthopedics Year: 2015 Type: Article Affiliation country: Brazil Institution/Affiliation country: Hospital Municipal Dr. Fernando Mauro Pires da Rocha/BR