Your browser doesn't support javascript.
loading
IDENTIFICACIÓN DE ZONAS SUSCEPTIBLES DE ABLACIÓN EN FIBRILACIÓN AURICULAR PERMANENTE IMPLEMENTANDO ENTROPÍA APROXIMADA EN UN MODELO 2D / IDENTIFICATION OF TARGET SITES FOR ABLATION DURING PERMANENT ATRIAL FIBRILLATION IMPLEMENTING APPROXIMATE ENTROPY IN A 2D MODEL / IDENTIFICAÇÃO DE ÁREAS SUSCETÍVEIS DE ABLAÇÃO PERMANENTE DE FIBRILAÇÃO ATRIAL NA IMPLEMENTAÇÃO ENTROPY APROXIMADO UM MODELO 2D
Palacio, Laura C; Tobón, Catalina; Orrego, Diana; Ugarte, Juan P; Orozco-Duque, Andrés; Bustamante, John.
  • Palacio, Laura C; Instituto Tecnológico Metropolitano. Grupo de Investigación e Innovación Biomédica. Medellín. CO
  • Tobón, Catalina; Instituto Tecnológico Metropolitano. Grupo de Investigación e Innovación Biomédica. Medellín. CO
  • Orrego, Diana; Instituto Tecnológico Metropolitano. Grupo de Investigación e Innovación Biomédica. Medellín. CO
  • Ugarte, Juan P; Instituto Tecnológico Metropolitano. Grupo de Investigación e Innovación Biomédica. Medellín. CO
  • Orozco-Duque, Andrés; Instituto Tecnológico Metropolitano. Grupo de Investigación e Innovación Biomédica. Medellín. CO
  • Bustamante, John; Instituto Tecnológico Metropolitano. Grupo de Investigación e Innovación Biomédica. Medellín. CO
Rev. ing. bioméd ; 8(16): 33-38, jul.-dic. 2014. graf
Article in Spanish | LILACS | ID: lil-769156
RESUMEN
La fibrilación auricular (FA) es la arritmia cardiaca más común. La ablación con catéter se ha convertido en la principal estrategia terapéutica para el tratamiento de la FA paroxística, sin embargo, los resultados en FA permanente no son completamente satisfactorios. Se propone la ablación de los electrogramas auriculares complejos fragmentados (CFAE) para la terminación de un rotor como mecanismo de mantenimiento de FA permanente. El objetivo de este trabajo es caracterizar los CFAE mediante la implementación de entropía aproximada (ApEn) y correlacionarlos con el tip de un rotor simulado. Para esto, se desarrolló un modelo 2D de tejido de aurícula humana bajo condiciones de FA permanente; se registraron electrogramas unipolares durante la actividad del rotor y se desarrolló un algoritmo para la medida de ApEn. La ApEn permitió localizar los CFAE con una alta precisión y relacionarlos con el tip del rotor. Por lo que este índice podría ser muy eficaz en la identificación de zonas susceptibles de ablación.
ABSTRACT
Atrial fibrillation (AF) is the most common cardiac arrhythmia. Catheter ablation has become the main therapeutic strategy for the treatment of paroxysmal AF, however, results in permanent AF are not completely satisfactory. Ablation of complex fractionated atrial electrograms (CFAE) is proposed for the termination of a rotor as mechanism of permanent AF maintenance. The aim of this work is to characterize the CFAE by implementing approximate entropy (ApEn) and to correlate with the tip of a simulated rotor. For this, a 2D model of human atrial tissue under permanent FA conditions was developed. Unipolar electrograms were recorded during the rotor activity and an algorithm to measure ApEn was developed. The ApEn allowed locate the CFAE with high precision and relate them to the tip of the rotor. So this index could be very effective in identifying target sites for ablation.
RESUMO
A fibrilação atrial (FA) é a arritmia cardíaca mais comum. A ablação por cateter tornou-se a principal estratégia terapêutica para o tratamento da fibrilação atrial paroxística, no entanto, resulta em FA permanente não são completamente satisfatórios. Ablação de fones de ouvido eletrocardiogramas complexos fragmentada (CFAE) para a conclusão de um rotor como um mecanismo de manutenção da FA permanente, é proposto. O objetivo deste trabalho é caracterizar o CFAE através da implementação de entropia aproximada (ApEn) e correlacioná-los com a ponta de um rotor simulado. Para isso, um modelo em 2D do tecido atrial humano sob condições de FA permanente desenvolvido; unipolares electrogramas foram registados durante a actividade do rotor e um algoritmo para medir ApEn desenvolvido. O ApEn permitido CFAE localizar com precisão elevada e relacioná-los com a ponta do rotor. Portanto, esta taxa pode ser muito eficaz na identificação de áreas suscetíveis a ablação.

Full text: Available Index: LILACS (Americas) Type of study: Diagnostic study Language: Spanish Journal: Rev. ing. bioméd Journal subject: Biotechnology / Biomedical Engineering Year: 2014 Type: Article Affiliation country: Colombia Institution/Affiliation country: Instituto Tecnológico Metropolitano/CO

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Type of study: Diagnostic study Language: Spanish Journal: Rev. ing. bioméd Journal subject: Biotechnology / Biomedical Engineering Year: 2014 Type: Article Affiliation country: Colombia Institution/Affiliation country: Instituto Tecnológico Metropolitano/CO