Your browser doesn't support javascript.
loading
Nivel de ruido en la unidad de cuidado intensivo adulto: Medición, estándares internacionales e implicancias sanitarias / Noise level in the intensive care unit for adults: measurement, international standards and health implications
Garrido-Galindo, Angélica Patricia; Camargo-Caicedo, Yiniva; Vélez-Pereira, Andrés M..
  • Garrido-Galindo, Angélica Patricia; Universidad del Magdalena. Santa Marta. CO
  • Camargo-Caicedo, Yiniva; Universidad del Magdalena. Santa Marta. CO
  • Vélez-Pereira, Andrés M.; Universidad del Magdalena. Santa Marta. CO
Univ. salud ; 17(2): 163-169, jul.-dic. 2015. ilus, tab
Article in Spanish | LILACS | ID: lil-774977
RESUMEN
Objetivo: Evaluar el nivel continuo equivalente de ruido en una unidad de cuidado intensivo adulto perteneciente a un hospital de la ciudad de Santa Marta con los niveles sugeridos por los estándares internacionales. Materiales y métodos: Se realizó un muestreo continuo durante 20 días registrando datos cada minuto con un sonómetro tipo I en un eje central de la unidad de cuidado intensivo adulto del hospital; los datos registrados correspondían a los valores máximos, mínimos y el nivel continuo equivalente de ruido en ponderación frecuencial A y el filtro de ponderación temporal Fast. Resultados: Se reporta que el nivel de ruido continuo equivalente varió entre 49 ­ 71 dBA con un valor máximo de 91,19 dBA y un mínimo de 46,65 dBA. El análisis de varianza infiere que el valor medio de ruido varía con la hora del día. Conclusiones: El nivel de ruido continuo equivalente presentado en la unidad de cuidado intensivo adulto es consistente con otros estudios similares, no obstante los valores presentados exceden los estándares internacionales de ruido sugeridos, generando una preocupación por los riesgos de exposición a los que se encuentran pacientes y personal médico de la unidad.
ABSTRACT
Objective: To assess the continuous equivalent noise level in an intensive care unit for adults that belongs to a hospital in the city of Santa Marta using the levels suggested by international standards. Materials and methods: A continuous sampling was done during 20 days where the data was recorded every minute by using a sound level meter type I in a central axis of the intensive care unit for adults in the hospital; the recorded data corresponded to the maximum, minimum values and the equivalent continuous level of noise on frequency weighting A and the Fast time weighting filter. Results: It was reported that the equivalent continuous noise level varied between 49-71 dBA with a maximum value of 91, 19 dBA and a minimum of 46, 65 dBA. The variance analysis infers that the mean value of noise varies according to the time of day. Conclusions: The level of equivalent continuous noise presented in the intensive care unit for adults is consistent with other similar studies; however, the displayed values exceed the international standards of noise suggested, which generates a concern about the risks of exposure for the patients as well as for the medical staff of the unit.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Public Health / Noise Monitoring / Critical Care / Noise, Occupational Type of study: Practice guideline Language: Spanish Journal: Univ. salud Journal subject: Medicine / Delivery of Health Care Year: 2015 Type: Article Affiliation country: Colombia Institution/Affiliation country: Universidad del Magdalena/CO

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Public Health / Noise Monitoring / Critical Care / Noise, Occupational Type of study: Practice guideline Language: Spanish Journal: Univ. salud Journal subject: Medicine / Delivery of Health Care Year: 2015 Type: Article Affiliation country: Colombia Institution/Affiliation country: Universidad del Magdalena/CO