Your browser doesn't support javascript.
loading
Effects of diaphragmatic control on the assessment of sniff nasal inspiratory pressure and maximum relaxation rate
Benício, Kadja; Dias, Fernando A. L; Gualdi, Lucien P; Aliverti, Andrea; Resqueti, Vanessa R; Fregonezi, Guilherme A. F.
  • Benício, Kadja; Universidade Federal do Rio Grande do Norte. Departamento de Fisioterapia. Natal. BR
  • Dias, Fernando A. L; Universidade Federal do Rio Grande do Norte. Departamento de Fisioterapia. Natal. BR
  • Gualdi, Lucien P; Universidade Federal do Rio Grande do Norte. Departamento de Fisioterapia. Natal. BR
  • Aliverti, Andrea; Universidade Federal do Rio Grande do Norte. Departamento de Fisioterapia. Natal. BR
  • Resqueti, Vanessa R; Universidade Federal do Rio Grande do Norte. Departamento de Fisioterapia. Natal. BR
  • Fregonezi, Guilherme A. F; Universidade Federal do Rio Grande do Norte. Departamento de Fisioterapia. Natal. BR
Braz. j. phys. ther. (Impr.) ; 20(1): 96-103, Jan.-Feb. 2016. tab, graf
Article in English | LILACS | ID: lil-778386
ABSTRACT
OBJECTIVE: To assess the influence of diaphragmatic activation control (diaphC) on Sniff Nasal-Inspiratory Pressure (SNIP) and Maximum Relaxation Rate of inspiratory muscles (MRR) in healthy subjects. METHOD: Twenty subjects (9 male; age: 23 (SD=2.9) years; BMI: 23.8 (SD=3) kg/m2; FEV1/FVC: 0.9 (SD=0.1)] performed 5 sniff maneuvers in two different moments: with or without instruction on diaphC. Before the first maneuver, a brief explanation was given to the subjects on how to perform the sniff test. For sniff test with diaphC, subjects were instructed to perform intense diaphragm activation. The best SNIP and MRR values were used for analysis. MRR was calculated as the ratio of first derivative of pressure over time (dP/dtmax) and were normalized by dividing it by peak pressure (SNIP) from the same maneuver. RESULTS: SNIP values were significantly different in maneuvers with and without diaphC [without diaphC: -100 (SD=27.1) cmH2O/ with diaphC: -72.8 (SD=22.3) cmH2O; p<0.0001], normalized MRR values were not statistically different [without diaphC: -9.7 (SD=2.6); with diaphC: -8.9 (SD=1.5); p=0.19]. Without diaphC, 40% of the sample did not reach the appropriate sniff criteria found in the literature. CONCLUSION: Diaphragmatic control performed during SNIP test influences obtained inspiratory pressure, being lower when diaphC is performed. However, there was no influence on normalized MRR.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Respiratory Muscles / Diaphragm / Inhalation / Inspiratory Capacity Limits: Humans Language: English Journal: Braz. j. phys. ther. (Impr.) Journal subject: MEDICINA FISICA E REABILITACAO Year: 2016 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal do Rio Grande do Norte/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Respiratory Muscles / Diaphragm / Inhalation / Inspiratory Capacity Limits: Humans Language: English Journal: Braz. j. phys. ther. (Impr.) Journal subject: MEDICINA FISICA E REABILITACAO Year: 2016 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal do Rio Grande do Norte/BR