Comparación de la actividad antimicrobiana de meropenem genérico y meropenem innovador por la técnica de micro dilución en cepas resistentes / Comparison of the antimicrobial activity of meropenem generic and innovative meropenem in resistant strains by micro dilution method
Rev. cuba. farm
;
49(4)oct.-dic. 2015.
Article
in Spanish
| LILACS, CUMED
| ID: lil-780743
RESUMEN
Objetivo:
comparar la actividad antimicrobiana de meropenem genérico y meropenem innovador, frente a cepas resistentes de interés clínico mediante la técnica de micro dilución.Método:
se determinó la concentración mínima inhibitoria y la concentración máxima bactericida según el protocolo de micro dilución del Clinical and Laboratory Standars Institute.Resultado:
se determinó una concentración mínima inhibitoria de 320 µg/mL y una concentración máxima bactericida de 640 µg/mL para Staphylococcus aureus con ambos antibióticos, Escherichia coli presentó una concentración mínima inhibitoria de 640 µg/mL y una concentración máxima bactericida de 1 280 µg/mL con los dos antibióticos y por último Klebsiella pneumoniae tuvo una concentración mínima inhibitoria de 5 120 µg/mL y una concentración máxima bactericida de 2 0480 µg/mL con ambos antibióticos.Conclusión:
no existen diferencias significativas en las concentración máxima bactericida y la concentración mínima inhibitoria de meropenem genérico y meropenem innovador(AU)ABSTRACT
Objective:
To compare the antimicrobial activity of generic meropenem and innovative meropenem on resistant strains of clinical interest by using the microdilution technique.Method:
The minimum inhibitory concentration and maximum bactericidal concentration were determined by the microdilution according to the protocol set by the Clinical and Laboratory Standards Institute (CLSI).Result:
Minimum inhibitory concentration (MIC) of 320 µg / mL and a maximum bactericidal concentration (MBC) of 640 µg/mL for both antibiotics against Staphylococcus aureus. MIC reached 640 µg/mL and MBC of 1 280 µg/mL in both antibiotics for Escherichia coli whereas the MIC was 5 120 µg/mL and WBC of 20 480 µg /mL with both antibiotics against Klebsiella pneumoniae.Conclusion:
No significant differences were observed in minimum inhibitory concentration and maximum bactericidal concentration between generic meropenem and innovative meropenem(AU)
Full text:
Available
Index:
LILACS (Americas)
Main subject:
Pseudomonas Infections
/
Reference Drugs
/
Anti-Infective Agents
Type of study:
Practice guideline
Limits:
Humans
Country/Region as subject:
South America
/
Colombia
Language:
Spanish
Journal:
Rev. cuba. farm
Journal subject:
Pharmacy
Year:
2015
Type:
Article
Affiliation country:
Colombia
Institution/Affiliation country:
Laboratorios Vitalis Phamaceutical/CO
/
Laboratorios Vitrofarma/CO
/
Universidad Javeriana/CO
Similar
MEDLINE
...
LILACS
LIS