Análise comparativa da avaliação da lordose lombar aferida na radiografia em ortostase e na ressonância magnética / Comparative analysis of assessment in computed radiography lumbar lordosis measuredn while standing and magnetic resonance imaging
Arq. bras. neurocir
;
33(4): 275-278, dez. 2014. tab
Article
in Portuguese
| LILACS
| ID: lil-782241
RESUMO
Objetivo:
Comparar os ângulos encontrados na radiografia em ortostase e na ressonância magnética (RM) em decúbito dorsal com coxim sobre os membros inferiores.Métodos:
Estudo prospectivo, de caráter descritivo, no qual se avaliou uma amostra de 100 pacientes, sendo 51 do sexo masculino, em que o grau de lordose lombar foi aferido por três examinadores independentes por meio da radiografia em ortostase e da RM em decúbito, com coxim, nos níveis de L1 a L5, de acordo com o método de Cobb.Resultados:
A média dos valores encontrados na radiografia e na RM com coxim de L1 a L5 foi de 42,2º e 31,5º, respectivamente (p < 0,001), demonstrando que a angulação da lordose lombar aferida na RM subdimensiona a verdadeira angulação em 25%.Conclusão:
A RM é insuficiente para a avaliação da lordose lombar, sendo de extrema importância a avaliação radiológica para avaliar a verdadeira angulação da lordose lombar.ABSTRACT
Objective:
To compare the angles found in radiography and magnetic resonance imaging (MRI) orthostatic supine with a pad on the lower limbs.Methods:
Measurement of lumbar lordosis angles from 100 patients referred to MRI and computed radiography studies, using Cobb?s method (with L1and L5 plateaus as reference). Measurements were done by three independent observers with different skills, and interobserver agreement was evaluated. The lumbar lordosis angle obtained in computedradiography and MRI were compared using statistical analysis with paired t-test.Results:
The mean lordosis angles measured in computed radiography and MRI were respectively 42.2º and 31.5º (p < 0.001).Conclusion:
There was good interobserver agreement. There was a statistically significantdifference between the angles of lumbar lordosis in computed radiography and MRI. The data suggest that MRI is not reliable in the evaluation of the lumbar lordosis when used alone.
Full text:
Available
Index:
LILACS (Americas)
Main subject:
Magnetic Resonance Spectroscopy
/
Lordosis
Type of study:
Observational study
Limits:
Adult
/
Aged
/
Female
/
Humans
/
Male
Language:
Portuguese
Journal:
Arq. bras. neurocir
Journal subject:
Cirurgia
/
Neurosurgery
Year:
2014
Type:
Article
Affiliation country:
Brazil
Institution/Affiliation country:
Centro de Diagnóstico por Imagem/BR
/
Hospital Santa Casa de Misericórdia/BR
/
Santa Casa de Misericórdia/BR
Similar
MEDLINE
...
LILACS
LIS