Your browser doesn't support javascript.
loading
Estudio comparativo entre los sistemas automatizados Vitek YBC® y Microscan Walk Away RYID® con los métodos fenotípicos convencionales para la identificación de levaduras de interés clínico / A comparative study between the Vitek YBC® and Microscan Walk Away RYID® automated systems with conventional phenotypic methods for the identification of yeasts of clinical interest
Ferrara, Giuseppe; Panizo, María Mercedes; Mazzone, Marja; Pequeneze, Maria Delia; Reviakina, Vera.
  • Ferrara, Giuseppe; Instituto Nacional de Higiene Rafael Rangel. Departamento de Micología. Caracas. VE
  • Panizo, María Mercedes; Instituto Nacional de Higiene Rafael Rangel. Departamento de Micología. Caracas. VE
  • Mazzone, Marja; Instituto Nacional de Higiene Rafael Rangel. Departamento de Micología. Caracas. VE
  • Pequeneze, Maria Delia; Instituto Nacional de Higiene Rafael Rangel. Departamento de Micología. Caracas. VE
  • Reviakina, Vera; Instituto Nacional de Higiene Rafael Rangel. Departamento de Micología. Caracas. VE
Invest. clín ; 55(4): 297-310, dic. 2014. tab
Article in Spanish | LILACS | ID: lil-783085
RESUMEN
El objetivo de este trabajo fue comparar la identificación de levaduras de interés clínico por los métodos automatizados Vitek YBC® y Microscan Walk Away RYID® con los métodos fenotípicos convencionales. Se utilizaron 193 aislamientos de levaduras provenientes de muestras clínicas y cinco cepas controles. Todas las levaduras fueron identificadas por los métodos automatizados antes nombrados y los métodos fenotípicos convencionales de asimilación de carbohidratos, visualización de la morfología microscópica con agar harina de maíz y el uso de agar cromogénico. Para evaluar las variables se utilizaron tablas de contingencia de 2×2, Chi cuadrado de Mc Nemar, el índice Kappa, y se calcularon los valores de concordancia, así como los errores mayores y menores de los métodos automatizados. Las levaduras se dividieron en dos grupos 1) de aislamiento frecuente y 2) de aislamiento poco frecuente. Los sistemas Vitek YBC® y Microscan Walk Away RYID® fueron concordantes en un 88,4 y 85,9% respectivamente, cuando se compararon con los métodos fenotípicos convencionales. Aunque ambos sistemas automatizados se pueden utilizar para la identificación de levaduras, la presencia de errores mayores y menores indica la posibilidad de identificaciones incorrectas, por lo tanto, el operador de estos equipos debe utilizar paralelamente pruebas fenotípicas como la visualización de la morfología microscópica en agar harina de maíz y el agar cromogénico, sobre todo frente a levaduras de aislamiento poco frecuente. Los sistemas automatizados son una herramienta valiosa, sin embargo, la experiencia y el criterio del microbiólogo son una fortaleza importante para asegurar la calidad de los resultados.
ABSTRACT
The aim of this study was to compare the identification of clinically relevant yeasts by the Vitek YBC® and Microscan Walk Away RYID® automated methods with conventional phenotypic methods. One hundred and ninety three yeast strains isolated from clinical samples and five controls strains were used. All the yeasts were identified by the automated methods previously mentioned and conventional phenotypic methods such as carbohydrate assimilation, visualization of microscopic morphology on corn meal agar and the use of chromogenic agar. Variables were assessed by 2×2 contingency tables, McNemar’s Chi square, the Kappa index, and concordance values were calculated, as well as major and minor errors for the automated methods. Yeasts were divided into two groups 1) frequent isolation and 2) rare isolation. The Vitek YBC® and Microscan Walk Away RYID® systems were concordant in 88.4 and 85.9% respectively, when compared to conventional phenotypic methods. Although both automated systems can be used for yeasts identification, the presence of major and minor errors indicates the possibility of misidentifications; therefore, the operator of this equipment must use in parallel, phenotypic tests such as visualization of microscopic morphology on corn meal agar and chromogenic agar, especially against infrequently isolated yeasts. Automated systems are a valuable tool; however, the expertise and judgment of the microbiologist are an important strength to ensure the quality of the results.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Reagent Kits, Diagnostic / Yeasts / Mycological Typing Techniques Type of study: Controlled clinical trial / Diagnostic study / Evaluation studies / Observational study / Prevalence study / Prognostic study / Risk factors Limits: Humans Language: Spanish Journal: Invest. clín Journal subject: Biologia / Medicine / Relatos de Casos Year: 2014 Type: Article Affiliation country: Venezuela Institution/Affiliation country: Instituto Nacional de Higiene Rafael Rangel/VE

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Reagent Kits, Diagnostic / Yeasts / Mycological Typing Techniques Type of study: Controlled clinical trial / Diagnostic study / Evaluation studies / Observational study / Prevalence study / Prognostic study / Risk factors Limits: Humans Language: Spanish Journal: Invest. clín Journal subject: Biologia / Medicine / Relatos de Casos Year: 2014 Type: Article Affiliation country: Venezuela Institution/Affiliation country: Instituto Nacional de Higiene Rafael Rangel/VE