Your browser doesn't support javascript.
loading
Biomecánica de la fijación distal en fracturas extrarticulares de radio: tornillos versus pernos. Estudio en modelos cadavéricos / Biomechanics of distal fixation in distal radius fracture: screws versus smooth pegs. Study in cadaveric models
Muratore, Alvaro; Gomez Rodriguez, Gustavo; Dal Lago, Javier; Robador, Nicolas; Nazur, Gabriel; Clembosky, Gabriel.
  • Muratore, Alvaro; Hospital Británico de Buenos Aires. Buenos Aires. AR
  • Gomez Rodriguez, Gustavo; Hospital Británico de Buenos Aires. Buenos Aires. AR
  • Dal Lago, Javier; Hospital Británico de Buenos Aires. Buenos Aires. AR
  • Robador, Nicolas; Hospital Británico de Buenos Aires. Buenos Aires. AR
  • Nazur, Gabriel; Hospital Británico de Buenos Aires. Buenos Aires. AR
  • Clembosky, Gabriel; Hospital Británico de Buenos Aires. Buenos Aires. AR
Article in Spanish | LILACS | ID: lil-784641
RESUMEN
Comparar biomecánicamente en modelos cadavéricos tornillos bloqueados con pernos bloqueados en fracturas extrarticulares de radio distal estabilizadas con placas bloqueadas volares. Materiales y

Métodos:

Se reprodujeron fracturas extrarticulares conminutas en 12 radios de seis cadáveres. Se formaron dos grupos según el empleo de tornillos bloqueados o pernos en la fijación distal. Se llevaron a cabo ensayos biomecánicos para evaluar cambios en la rigidez del montaje después de realizar una carga axial. Finalmente, se llevó el sistema al fallo. Se efectuaron controles radiológicos en todas las etapas.

Resultados:

Al llevarlos al fallo, el sistema con tornillos presentó una mayor desviación hacia dorsal de la carilla articular en el perfil. Se observó una separación de la placa en relación con el hueso en las placas montadas con pernos. La carga máxima tolerada fue de 1659 N y de 1905 N con los tornillos bloqueados y con los pernos, respectivamente.

Conclusiones:

En ambos sistemas, se observó que la fuerza de carga pasa de la epífisis a la diáfisis a través del material de osteosíntesis (hueso-placa-hueso), puenteando la fractura y deformando la placa que empuja la carilla articular hacia una inclinación dorsal. Sin embargo, en los modelos fijados con pernos, se encontró un segundo tiempo de transmisión de fuerza en el cual la placa se separa del sistema debido al deslizamiento de los pernos lisos, lo que posibilita una transmisión directamente del fragmento distal al proximal (hueso-hueso) que produce, en todos los casos, una fractura incompleta y longitudinal de la cortical volar, pero que evita seguir deformando la placa hacia el dorso. Nivel de Evidencia II...
ABSTRACT
To perform a biomechanical comparison in cadaveric models between locking screws and locking smooth pegs in extra-articular distal radius fractures stabilized with volar locking plates.

Methods:

We reproduced extra-articular dorsal comminuted fractures in 12 cadaveric radius. We divided them into two groups according to the use of locking screws or locking smooth pegs in distal fixation. Biomechanical tests were conducted evaluating changes in the rigidity of the systems after performing an axial load. Finally, the systems were led to the failure. Radiological controls were performed in all instances.

Results:

When the systems fixed with locking screws were led to the failure, a greater dorsal inclination of the articular facet was observed. A separation of the plate relative to the bone was observed in those plates fixed with locking smooth pegs. Moreover, the maximum tolerated load was 1659 N and 1905 N in the systems with locking screws and with locking smooth pegs, respectively.

Conclusions:

In both systems the load force moves from the epiphysis to the diaphysis through the osteosynthesis (bone-plate-bone), bridging the fracture and deforming the plate which pushes the articular facet to dorsal deviation. However, in models with locking smooth pegs we found a second time of load transmission in which the plate is removed from the system due to slippage of the locking smooth peg, allowing a transmission directly from the distal to the proximal fragment (bone-bone) generating in all cases an incomplete and longitudinal fracture of the volar cortex, but avoiding deformation of the plate to dorsal deviation. Level of Evidence II...
Subject(s)
Full text: Available Index: LILACS (Americas) Main subject: Radius Fractures / Wrist Injuries / Biomechanical Phenomena / Bone Plates / Bone Screws / Fracture Fixation, Internal Limits: Humans Language: Spanish Journal: Rev. Asoc. Argent. Ortop. Traumatol Journal subject: Orthopedics Year: 2015 Type: Article Affiliation country: Argentina Institution/Affiliation country: Hospital Británico de Buenos Aires/AR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Radius Fractures / Wrist Injuries / Biomechanical Phenomena / Bone Plates / Bone Screws / Fracture Fixation, Internal Limits: Humans Language: Spanish Journal: Rev. Asoc. Argent. Ortop. Traumatol Journal subject: Orthopedics Year: 2015 Type: Article Affiliation country: Argentina Institution/Affiliation country: Hospital Británico de Buenos Aires/AR