Your browser doesn't support javascript.
loading
Fracturas alrededor de una osteosíntesis extramedular previa de fémur proximal: una solución simple para un problema complejo / Fractures around a previous proximal femur fixation: a simple solution to a complex problem
Bidolegui, Fernando; Calvo, Ximena; Pereira, Sebastian; Vindver, Gabriel.
  • Bidolegui, Fernando; Hospital Sirio Libanés. Departamento de Trauma Ortopédico. Buenos Aires. AR
  • Calvo, Ximena; Hospital Sirio Libanés. Departamento de Trauma Ortopédico. Buenos Aires. AR
  • Pereira, Sebastian; Hospital Sirio Libanés. Departamento de Trauma Ortopédico. Buenos Aires. AR
  • Vindver, Gabriel; Hospital Sirio Libanés. Departamento de Trauma Ortopédico. Buenos Aires. AR
Article in Spanish | LILACS, BINACIS | ID: lil-789901
RESUMEN
El número de fracturas de cadera en pacientes ancianos aumenta proporcionalmente al incremento de la expectativa de vida. Por lo tanto, no resulta infrecuente hallar una fractura de fémur, distal a un implante de osteosíntesis extramedular (clavo compresivo deslizante o clavo placa de ángulo fijo) previamente colocado en fracturas intertrocantérica o subtrocantérica de cadera, pese a la tasa de mortalidad anual comunicada del 30-50 % en los pacientes con fractura de cadera. Ante dicha situación, hemos utilizado un clavo endomedular retrógrado asociado a la extracción, de forma percutánea, de los tornillos del implante previo. Se presentan ocho casos de fracturas periosteosíntesis en pacientes con una edad promedio de 85.6 años (5 mujeres y 3 hombres) y un tiempo promedio desde la osteosíntesis de fémur proximal hasta la fractura periosteosíntesis de 3.5 años. El seguimiento fue de 36 meses y se evaluaron la movilidad y el dolor posoperatorios. Se logró la consolidación de la fractura en todos los casos. Dicho procedimiento nos ha resultado una técnica eficaz, se puede lograr una fijación estable sin agregar morbilidad debido a la posibilidad de solapar los dos implantes y disminuir el potencial riesgo de una nueva fractura interimplantes.
ABSTRACT
The number of hip fractures in the elderly elevates as life expectancy increases. Therefore it is not infrequent to observe a femur fracture, distal to a previous proximal femur fixation (dynamic hip screw or fixed angle plate) used in intertrochanteric femur fractures, despite the reported annual mortality rate of 30-50% in patients with a femoral fracture. Given this situation, we used a retrograde intramedullary nail together with the percutaneous removal of previously implanted screws. We present eight cases of peri-osteosynthesis fractures in patients with an average age of 85.6 years (5 women and 3 men) and an average time from the proximal femur fixation to the new fracture of 3.5 years. The follow-up was 36 months and postoperative motion and pain were evaluated. Consolidation of the fracture was achieved in all cases. We found this technique effective; it was possible to achieve a stable fixation without adding morbidity due to the possibility of overlapping two implants, thus reducing the potential risk of a new fracture between implants.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Periprosthetic Fractures / Fracture Fixation, Internal / Hip Fractures Limits: Aged / Aged80 Language: Spanish Journal: Rev. Asoc. Argent. Ortop. Traumatol Journal subject: Orthopedics Year: 2016 Type: Article Affiliation country: Brazil Institution/Affiliation country: Hospital Sirio Libanés/AR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Periprosthetic Fractures / Fracture Fixation, Internal / Hip Fractures Limits: Aged / Aged80 Language: Spanish Journal: Rev. Asoc. Argent. Ortop. Traumatol Journal subject: Orthopedics Year: 2016 Type: Article Affiliation country: Brazil Institution/Affiliation country: Hospital Sirio Libanés/AR