Your browser doesn't support javascript.
loading
Evaluación del ambiente electromagnético en salas de rehabilitación / Evaluation of the electromagnetic environment in rehabilitation wards
Deás Yero, Douglas; Gilart González, Fidel; Beira Fontaine, Leonardo.
Affiliation
  • Deás Yero, Douglas; Universidad de Oriente. Centro Nacional de Electromagnetismo Aplicado. Santiago de Cuba. CU
  • Gilart González, Fidel; Universidad de Oriente. Centro Nacional de Electromagnetismo Aplicado. Santiago de Cuba. CU
  • Beira Fontaine, Leonardo; Universidad de Oriente. Dirección Municipal de Electromedicina, municipio Palma Soriano, Santiago de Cuba. Santiago de Cuba. CU
Medisan ; 20(8)ago.-ago. 2016. ilus
Article in Es | LILACS, CUMED | ID: lil-794094
Responsible library: CU418.1
RESUMEN
Se realizó un estudio del ambiente electromagnético en 2 departamentos de electroterapia del municipio Palma Soriano de Santiago de Cuba, a fin de obtener el patrón de distribución para diferentes modos de operatividad y explotación del equipamiento médico-terapéutico. Para la caracterización electromagnética de los ambientes evaluados se elaboró un protocolo de medición a partir del análisis de normas internacionales y se empleó un medidor isotrópico que mostró los resultados a través de mapas de contorno. El equipo electromédico Magnetomed, modelo 7200 fue el que más aportó, aunque el valor máximo de la inducción magnética obtenido (19,7 µT) estuvo por debajo del límite de exposición establecido y por encima del límite de exposición sugerido por el Grupo de Trabajo Bioiniciativa. Se recomienda limitar la permanencia de personas en sus proximidades mientras está en funcionamiento.
ABSTRACT
A study of the electromagnetic environment was carried out in 2 electrotherapy departments of Palma Soriano in Santiago de Cuba, in order to obtain the distribution pattern for different operability ways and exploitation of the medical-therapeutic equipment. For the electromagnetic characterization of the evaluated environments a measurement protocol was elaborated starting from the analysis of international standards and an isotropic measure was used that showed the results through contour maps. The electro-medical device Magnetomed, model 7200 was the one that contributed the most, although the maximum value of the obtained magnetic induction (19.7 µT) was below the established exhibition limit and above the exhibition limit suggested by the Bioiniciativa Work Group. It is recommended to limit the permanency of people around, while it is in operation.
Subject(s)
Key words
Full text: 1 Index: LILACS Main subject: Electrical Equipment and Supplies / Health Facility Environment Type of study: Guideline Language: Es Journal: Medisan Journal subject: MEDICINA Year: 2016 Type: Article
Full text: 1 Index: LILACS Main subject: Electrical Equipment and Supplies / Health Facility Environment Type of study: Guideline Language: Es Journal: Medisan Journal subject: MEDICINA Year: 2016 Type: Article