Your browser doesn't support javascript.
loading
Use of optimized ultrasound axis along with marked introducer needle to prevent mechanical complications of internal jugular vein catheterization.
Ann Card Anaesth ; 2013 Oct; 16(4): 296-298
Article in English | IMSEAR | ID: sea-149673
ABSTRACT
Internal jugular vein (IJV) catheterization is a routine technique in the intensive care unit. Ultrasound (US) guided central venous catheter (CVC) insertion is now the recommended standard. However, mechanical complications still occur due to non‑visualization of the introducer needle tip during US guidance. This may result in arterial or posterior venous wall puncture or pneumothorax. We describe a new technique of (IJV) catheterization using US, initially the depth of the IJV from the skin is measured in short‑axis and then using real time US long‑axis view guidance a marked introducer needle is advanced towards the IJV to the defined depth measured earlier in the short axis and the IJV is identified, assessed and cannulated for the CVC insertion. Our technique is simple and may reduce mechanical complications of US guided CVC insertion.
Subject(s)

Full text: Available Index: IMSEAR (South-East Asia) Main subject: Humans / Male / Catheterization, Central Venous / Adult / Jugular Veins Language: English Journal: Ann Card Anaesth Year: 2013 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: IMSEAR (South-East Asia) Main subject: Humans / Male / Catheterization, Central Venous / Adult / Jugular Veins Language: English Journal: Ann Card Anaesth Year: 2013 Type: Article