A Validated Ion Chromatography method for determination of Ammonium content.
Article
in English
| IMSEAR
| ID: sea-157325
ABSTRACT
A simple, feasible, definite and strong Ion chromatography method was developed for the quantitative determination of ammonium content in Omeprazole tablets. The method was developed using Ion pac CS17 Column, 250 X 4.6mm X 5.0 mm column with mobile phase containing 1.5mM Methane sulfonic acid in water. The eluted compounds were monitored using conductivity detector. The unknown peak and ammonium peak were well separated with resolution more than 2.0. The developed method was validated as per Internatonal Conference on Harmonisation of technical Requirements for registration of pharmaceuticals for human use guidelines with respect to linearity (The high correlation coefficient >0.99), limit of detection, limit of quantification, exactness, precision and robustness. The Limit of detection, Limit of quantification values of Ammonium were 8ppm and 30ppm respectively.
Full text:
Available
Index:
IMSEAR (South-East Asia)
Language:
English
Year:
2014
Type:
Article
Similar
MEDLINE
...
LILACS
LIS