Your browser doesn't support javascript.
loading
Results of proximal humeral locking plate fixation in Neer’s two and three part proximal humerus fractures: A retrospective analysis of twenty patients.
Article in English | IMSEAR | ID: sea-164650
ABSTRACT

Background:

Fractures of the proximal humerus have been a challenge to orthopaedic sugeons with treatment modalities changing from time to time. Locking plates have revolutionised the treatment of these fractures. Currently proximal humeral locking plates (PHLP) and proximal humeral interlocking osteosynthesis (PHILOS) are two types of locking plates available for fixation of these fractures. Aim of this study was to evaluate the results of proximal humeral locking plate (PHLP) for Neers’s two and three part proximal humerus fractures. Material and

methods:

Neer’s two and three part fractures treated by open reduction and internal fixation with proximal humeral locking plate from August 2012 to April 2014 were retrospectively evaluated for complications, time to radiological union and final functional outcome using Constant Murley Score (CMS).

Results:

Twenty (12 male; 8 female) patients with 8 Neer’s 2-part and 12 neer's 3- part fractures managed by open reduction and internal fixation with proximal humeral locking plate (PHLP) with an average follow up of 23.2 months were evaluated. All the fractures united at an average of 16 (12 to 20) weeks. Eight complications were seen in 5 (25%) patients, namely, inadequate anatomical reduction (n = 1), superficial wound infection (n = 1), deep infection (n = 1), subacromial impingement (n = 1), axillary nerve neuropraxia (n = 1), adhesive capsulitis (n = 1) and secondary varus collapse (n = 2). There was no patient who developed avascular necrosis (AVN), non- unioun, primary or secondary screw perforation, implant failure and vascular injury. Average Constant-Murley Score at final follow up was 84.75 ± 11.6. 85% patients had very good and Good functional results. No patient had poor functional results.

Conclusion:

Proximal humeral locking plate (PHLP) is an excellent implant in Neer’s two and three part fractures of the proximal humerus. Complications can be minimized by meticulous Surgical technique and proper placement of screws and plate. In case of medial comminution, use of PHILOS with placement of medial support screws and bone grafting should be preferred to prevent varus collapse.

Full text: Available Index: IMSEAR (South-East Asia) Language: English Year: 2015 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: IMSEAR (South-East Asia) Language: English Year: 2015 Type: Article