Wire-Aided Reintubation Following Rigid Bronchoscopy: A Safe Technique.
Indian Pediatr ; 2012 December; 49(12): 983-985
Article in English | IMSEAR | ID: sea-169595
ABSTRACT
The management of a neonate with a known difficult airway is a challenge to any clinician. We report a four-day-old neonate with a known difficult airway, who presented to us for rigid bronchoscopy. We used an innovative, economical and easily available adult central venous line guidewire to secure the airway and reintubate the child.

Full text: Available Index: IMSEAR (South-East Asia) Language: English Journal: Indian Pediatr Year: 2012 Type: Article