Your browser doesn't support javascript.
loading
Electric Current Causing Sigmoid Perforation: Case Report.
Article in English | IMSEAR | ID: sea-174691
ABSTRACT
Post electric burn sigmoid perforation is a rare but dreadful complication. It can lead to increased chances of mortality/morbidity if any delay is made during diagnosis or active management. We report a case of electric current burn on left hand, forearm, arm and shoulder with perforation of sigmoid colon with successful management by primary closure.

Full text: Available Index: IMSEAR (South-East Asia) Language: English Year: 2015 Type: Article

Similar

MEDLINE

...
LILACS

LIS