Your browser doesn't support javascript.
loading
Aortic rupture during endovascular repair of a postoperative coarctation pseudoaneurysm in an adult: Emergency lifesaving stent graft implantation
Ann Card Anaesth ; 2019 Apr; 22(2): 225-228
Article | IMSEAR | ID: sea-185886
ABSTRACT
We present a case with aortic rupture during an operation of thoracic endovascular aortic repair of an anastomotic pseudoaneurysm. This happened after the use of a low-pressure remodeling balloon inside the covered part of the deployed endografts. It was successfully treated with a second more centrally in the aortic arch-implanted endograft with full coverage of the left subclavian artery orifice. This patient had a history of surgically operated aortic coarctation.

Full text: Available Index: IMSEAR (South-East Asia) Journal: Ann Card Anaesth Year: 2019 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: IMSEAR (South-East Asia) Journal: Ann Card Anaesth Year: 2019 Type: Article