Aortic rupture during endovascular repair of a postoperative coarctation pseudoaneurysm in an adult: Emergency lifesaving stent graft implantation
Ann Card Anaesth
;
2019 Apr; 22(2): 225-228
Article
| IMSEAR
| ID: sea-185886
ABSTRACT
We present a case with aortic rupture during an operation of thoracic endovascular aortic repair of an anastomotic pseudoaneurysm. This happened after the use of a low-pressure remodeling balloon inside the covered part of the deployed endografts. It was successfully treated with a second more centrally in the aortic arch-implanted endograft with full coverage of the left subclavian artery orifice. This patient had a history of surgically operated aortic coarctation.
Full text:
Available
Index:
IMSEAR (South-East Asia)
Journal:
Ann Card Anaesth
Year:
2019
Type:
Article
Similar
MEDLINE
...
LILACS
LIS