Stenting of patent ductus arteriosus in low birth weight newborns less than 2 kg- procedural safety, feasibility and results in a retrospective study
Indian Heart J ; 2018 Sep; 70(5): 709-712
Article | IMSEAR | ID: sea-191670
ABSTRACT
Objective Retrospective analysis of the feasibility, safety and results of patent ductus arteriosus (PDA) stenting in low birth weight babies weighing < 2 kg.

Background:

Stenting of patent ductus arteriosus is a well known palliative technique for several years as an alternative to shunt surgery in babies weighing > 2.5–3 kg. Ductal stenting in babies weighing less than 2 kg is not done routinely all around the world due to limited experience and concerns regarding its feasibility and safety in such small subset. Methods Records of patients who underwent PDA stenting at our institution from June 2014 to December 2016 were reviewed. In this period, we attempted to do PDA stenting using femoral artery approach in babies weighing < 2 kg. Echocardiography and colour Doppler were used for patient selection and assessment of procedural outcome. Results PDA stenting using femoral artery approach was successful in all 5 patients weighing < 2 kg. In this group, patient age ranged from 2 days to 16 days and weighed 1.8 kg to 1.97 kg. All patients had good post-procedure outcome. One patient had stent malposition from aortic end towards main pulmonary artery which was managed by an additional stent. Conclusion PDA stenting is feasible and safe with good end results in carefully selected low birth weight babies weighing < 2 kg.

Full text: Available Index: IMSEAR (South-East Asia) Type of study: Observational study Journal: Indian heart j Year: 2018 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: IMSEAR (South-East Asia) Type of study: Observational study Journal: Indian heart j Year: 2018 Type: Article