Your browser doesn't support javascript.
loading
Safety and efficacy of dexamethasone implant along with phacoemulsification and intraocular lens implantation in children with juvenile idiopathic arthritis associated uveitis
Indian J Ophthalmol ; 2019 Jan; 67(1): 69-74
Article | IMSEAR | ID: sea-197054
ABSTRACT

Purpose:

To assess the safety and efficacy of intraoperative intravitreal dexamethasone implant in patients of juvenile idiopathic arthritis (JIA)-associated uveitis undergoing phacoemulsification with posterior chamber intraocular lens (PCIOL) implantation.

Methods:

Retrospectively, data of patients with JIA-associated uveitis undergoing phacoemulsification with PCIOL implantation with intraoperative dexamethasone implant injection were analyzed. Patients with a minimum follow-up of 6 months were included. Primary outcome measures were ocular inflammation, intraocular pressure (IOP), best-corrected visual acuity (BCVA), and worsening of uveitis.

Results:

8 eyes of 6 patients were included. BCVA was significantly improved at 1, 3, and 6 months postoperatively 0.20 ± 0.09, P = 0.008; 0.18 ± 0.11, P = 0.008; and 0.24 ± 0.11, P = 0.01, respectively. No statistical difference noted in mean IOP at various follow-up visits. None developed worsening of uveitis or Cystoid macular edema.

Conclusion:

Intraoperative intravitreal dexamethasone implant is a safe and effective in preventing and managing the postoperative inflammation in children with JIA-associated uveitic cataract.

Full text: Available Index: IMSEAR (South-East Asia) Journal: Indian J Ophthalmol Year: 2019 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: IMSEAR (South-East Asia) Journal: Indian J Ophthalmol Year: 2019 Type: Article