Your browser doesn't support javascript.
loading
Silicone band loop myopexy for myopic strabismus fixus
Indian J Ophthalmol ; 2019 Jul; 67(7): 1155-1157
Article | IMSEAR | ID: sea-197363
ABSTRACT
Myopic strabismus fixus causes inability of the eye to elevate and abduct in the setting of a myopic superotemporally herniated globe. We report a novel surgical technique to manage an 18-year-old male with myopic strabismus fixus. Radiological imaging demonstrated a nasally deviated superior rectus (SR) and inferiorly displaced lateral rectus (LR). Silicone band assisted myopexy of SR and LR was done along with anchoring them to the sclera with a dacron suture. The patient had satisfactory alignment postoperatively and did not require any intervention over 1-year follow-up.

Full text: Available Index: IMSEAR (South-East Asia) Journal: Indian J Ophthalmol Year: 2019 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: IMSEAR (South-East Asia) Journal: Indian J Ophthalmol Year: 2019 Type: Article