Your browser doesn't support javascript.
loading
Groin dressing after cardiac catheterization. Comparison between light dressing with thin transparent tape (Tegaderm) and conventional tight/pressure dressing with an elastic adhesive bandage (Tensoplast).
Article in English | IMSEAR | ID: sea-39081
ABSTRACT
Post cardiac catheterization puncture site care is usually done with a tight pressure dressing by an elastic adhesive bandage (Tensoplast) due to the belief that it should prevent bleeding. The practice is uncomfortable to the patients. The authors compared a new way of dressing using light transparent tape (Tegaderm) to the conventional tight pressure one. 126 post coronary angiography patients were randomized to have their groins dressed either with Tensoplast or with Tegaderm. Patients ambulated 8 hours after the procedures. The groin was evaluated for pain, discomfort and bleeding complications. 49 per cent in the Tensoplast vs 26.9 per cent in the Tegaderm group experienced pain (p value of 0.01). 55.5 per cent in the Tensoplast group vs 11.1 per cent in the Tegaderm group reported discomfort. 4.7 per cent in the Tensoplast vs 1.6 per cent in the Tegaderm group developed bleeding or hematoma. Dressing of the puncture site after cardiac catheterization with Tegaderm was more comfortable than the conventional Tensoplast without any difference in bleeding complications.
Subject(s)
Full text: Available Index: IMSEAR (South-East Asia) Main subject: Pressure / Bandages / Aged / Female / Humans / Male / Cardiac Catheterization / Adhesives / Needlestick Injuries / Groin Type of study: Controlled clinical trial Language: English Year: 2001 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: IMSEAR (South-East Asia) Main subject: Pressure / Bandages / Aged / Female / Humans / Male / Cardiac Catheterization / Adhesives / Needlestick Injuries / Groin Type of study: Controlled clinical trial Language: English Year: 2001 Type: Article