Your browser doesn't support javascript.
loading
Balloon valvuloplasty of stenosed Carpentier-Edwards bioprosthesis at pulmonary position.
Indian Heart J ; 2004 Mar-Apr; 56(2): 147-9
Article in English | IMSEAR | ID: sea-3989
ABSTRACT
Bioprostheses frequently become calcified and stenosed, especially when implanted in younger patients. The general recommendation in such cases is to repeat surgery. Balloon valvuloplasty has hitherto been attempted with mixed success. Calcification and limitation of the balloon size due to the valve ring can lead to suboptimal long-term results. We report a case where balloon dilation of the stenosed bioprosthesis at pulmonary position was successfully performed with good immediate result. Cardiac catheterization after 3 years showed only a minimal increase (5 mmHg) in the gradient.
Subject(s)
Full text: Available Index: IMSEAR (South-East Asia) Main subject: Pulmonary Artery / Pulmonary Valve Stenosis / Abnormalities, Multiple / Bioprosthesis / Prosthesis Failure / Humans / Male / Heart Valve Prosthesis / Cardiac Catheterization / Echocardiography, Doppler Type of study: Etiology study / Observational study / Prognostic study / Risk factors Language: English Journal: Indian heart j Year: 2004 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: IMSEAR (South-East Asia) Main subject: Pulmonary Artery / Pulmonary Valve Stenosis / Abnormalities, Multiple / Bioprosthesis / Prosthesis Failure / Humans / Male / Heart Valve Prosthesis / Cardiac Catheterization / Echocardiography, Doppler Type of study: Etiology study / Observational study / Prognostic study / Risk factors Language: English Journal: Indian heart j Year: 2004 Type: Article