Translaryngeal retrograde wire-guided fiberoptic intubation for difficult airway: a case report.
Article in English | IMSEAR | ID: sea-44091
ABSTRACT
The authors describe the special tracheal intubation technique used in two patients with a difficult airway. These are the translaryngeal retrograde wire-guided and fiberoptic intubation. The authors show how to use both to facilitate intubation. The authors modified the technique by passing a guide-wire in a retrograde manner from the trachea to the nose and then a fiberoptic laryngoscope within the endotracheal tube over the wire. The technique can be applied for use in any difficult airway situation.
Subject(s)
Full text: Available Index: IMSEAR (South-East Asia) Main subject: Female / Humans / Male / Adult / Laryngoscopes / Airway Obstruction / Fiber Optic Technology / Intubation, Intratracheal Language: English Year: 2005 Type: Article