Plasma pharmacokinetics of a generic amoxycillin and the innovator brand: a comparison.
Ceylon Med J
;
1998 Mar; 43(1): 16-8
Article
in English
| IMSEAR
| ID: sea-48191
ABSTRACT
OBJECTIVE:
To compare the bioavailability and plasma pharmacokinetics of a generic brand of amoxycillin (State Pharmaceutical Manufacturing Coporation) selected from the lower price range, with that of the innovation brand (Amoxil, Beecham).DESIGN:
Sixteen healthy adult volunteers were allotted to two groups and each group was given a test dose of amoxycillin from each brand. Blood samples were collected at 0, 2, 3 and 4 hours thereafter plasma levels were assayed using high performance liquid chromatography.RESULTS:
Analysis of results show that the generic product had similar bioavailability and pharmacokinetics when compared with the innovator product.CONCLUSION:
The quality assured generic amoxycillin tested had similar bioavailability as a more costly branded version.