Modification of the "wrap around" tendon anastomosis of fascia lata graft with a slim double tendon of palmaris longus.
Indian J Lepr
;
1999 Jul-Sep; 71(3): 337-40
Article
in English
| IMSEAR
| ID: sea-55419
ABSTRACT
A modification of Brand's "wrap around" technique of anastomosis is described, which allows joining a double tendon or split tendon of palmaris longus to fascia lata graft, when one of the slim tendons would not allow performance of the Brand tendon anastomosis. Four such cases have been done successfully.