Your browser doesn't support javascript.
loading
Usefulness of Single Voxel Pro ton MR Spectroscopy in the Evaluation of Hippocampal Sclerosis
Article in En | WPRIM | ID: wpr-100198
Responsible library: WPRO
ABSTRACT
OBJECTIVE: The purpose of our study was to determine the ability of H-1 MR spectroscopy (MRS) to lateralize the lesion in patients with hippocampal sclerosis. MATERIALS AND METHODS: Twenty healthy volunteers and 25 patients with intractable temporal lobe epilepsy whose MR imaging diagnosis was unilateral hippocampal sclerosis were included. This diagnosis was based on the presence of unilateral atrophy and/or high T2 signal intensity of the hippocampus. Single-voxel H-1 MRS was carried out on a 1.5-T unit using PRESS sequence (TE, 136 msec). Spectra were obtained from hippocampal areas bilaterally with volumes of interest (VOIs) of 6.0 cm 3and 2.25 cm 3 in healthy volunteers, and of either 6.0 c m 3 (n = 14) or 2.25 cm 3 (n = 11) in patients. Metabolite ratios of NAA/Cho and NAA/Cr were calculated from relative peak height measurements. The capability of MRS to lateralize the lesion and to detect bilateral abnormalities was compared with MR imaging diagnosis as a standard of reference. RESULTS: In healthy volunteers, NAA/Cho and NAA/Cr ratios were greater than 0.8 and 1.0, respectively. In patients, the mean values of these ratios were significantly lower on the lesion side than on the contralateral side, and lower than those of healthy volunteers (p <.05). The overall correct lateralization rate of MRS was 72% (18/25); this rate was lower with a VOI of 6.0 cm 3 than of 2.25 cm 3 (64% versus 82%, p <.05). Bilateral abnormalities on MRS were found in 24% (6/25) of cases. CONCLUSION: Although its rate of correct lateralization is low, single-voxel H-1 MRS is a useful and promising diagnostic tool in the evaluation of hippocampal sclerosis, particularly for the detection of bilateral abnormalities. To improve the diagnostic accuracy of H-1 MRS, further investigation, including the use of a smaller VOI and measurement of the absolute amount of metabolites, are needed.
Subject(s)
Key words
Full text: 1 Index: WPRIM Main subject: Sclerosis / Magnetic Resonance Spectroscopy / Case-Control Studies / Epilepsy, Temporal Lobe / Hippocampus Type of study: Observational_studies Limits: Adult / Female / Humans / Male Language: En Journal: Korean Journal of Radiology Year: 2000 Type: Article
Full text: 1 Index: WPRIM Main subject: Sclerosis / Magnetic Resonance Spectroscopy / Case-Control Studies / Epilepsy, Temporal Lobe / Hippocampus Type of study: Observational_studies Limits: Adult / Female / Humans / Male Language: En Journal: Korean Journal of Radiology Year: 2000 Type: Article