Your browser doesn't support javascript.
loading
HIV-, HBV- and HCV- NAT yield in individual donations: a multi-center analysis in Henan province from 2017 to 2019 / 中国输血杂志
Chinese Journal of Blood Transfusion ; (12): 68-72, 2021.
Article in Chinese | WPRIM | ID: wpr-1003928
ABSTRACT
【Objective】 To analyze the HIV-, HCV- and HBV- NAT yield rate in different areas of Henan province, so as to provide the basis for disease prevention and control as well as the establishment of a unified quality control standard for nucleic acid testing(NAT) in the Henan province. 【Methods】 The number and prevalence of NAT yielding samples with isolated infectious virus, namely HIV, HCV and HBV, in 18 blood stations in Henan province from 2017~2019, as well as the trends were analyzed. The NAT quality of each laboratory and each testing system was analyzed according to the ratio of reactive individual donation(ID) results to reactive minipools(MP). 【Results】 The HBV, HCV and HIV ID-NAT yield numbers in 3 501 251 blood donations were HBV 2 606(74/100 000), HCV 21 (0.63/100 000), and HIV 34(1.00/100 000). The HBV ID-NAT yield rate showed an upward trend in the whole province from 2017 to 2019, while the prevalence of HIV and HCV ID-NAT yield didn′t differ significantly during three years. 5 kinds of NAT detection systems were applied in 18 blood centers. among which Ⅰ, Ⅱ, Ⅳ and Ⅴ were triplex detection systems. 2661 ID-reactive samples were implicated in 5 595 MP-reactive samples, with a resolution rate of 47.56%. The resolution rate of triplex NAT system Ⅰ, Ⅱ, Ⅳ and Ⅳ was 39.63%~47.95%, 40.43%~54.36%, 51.61% and 70.00%~45.45%, respectively. An upward trend in triplex NAT resolution rate was observed in 8 laboratories, i. e.B, D, E, F, I, K, L and Q, and an descending trend in A and C. The NAT system Ⅲ, a ID-NAT system, was used only by laboratory C, presenting a NAT-yield rate of 0.19% (282/145 474) and resolution rate of 46.45% (131/282). 【Conclusion】 The majority of NAT-yield of one infectious virus in Henan province is HBV, presenting annual increasing trend. The quality management of NAT laboratories should be strengthened as the divergence was seen in the performance of different NAT laboratories.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Blood Transfusion Year: 2021 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Blood Transfusion Year: 2021 Type: Article