Your browser doesn't support javascript.
loading
Triangular Fixation Technique for Bicolumn Restoration in Treatment of Distal Humerus Intercondylar Fracture
Clinics in Orthopedic Surgery ; : 9-18, 2016.
Article in English | WPRIM | ID: wpr-101620
ABSTRACT

BACKGROUND:

Distal humerus intercondylar fractures are intra-articular and comminuted fractures involving soft tissue injury. As distal humerus is triangle-shaped, parallel plating coupled with articular fixation would be suitable for bicolumn restoration in treatment of distal humerus intercondylar fracture.

METHODS:

This study included 38 patients (15 males and 23 females) who underwent olecranon osteotomy, open reduction and internal fixation with the triangle-shaped cannulated screw and parallel locking plates (triangular fixation technique). Functional results were assessed with the visual analog scale (VAS) scores, Mayo elbow performance (MEP) scores and Disabilities of the Arm, Shoulder and Hand (DASH) questionnaires. Anteroposterior and lateral elbow radiographs were assessed for reduction, alignment, fracture union, posttraumatic arthrosis, and heterotopic ossification, and computed tomography (CT) scans were used to obtain more accurate measurements of articular discrepancy.

RESULTS:

All fractures healed primarily with no loss of reduction. The mean VAS, MEP, and DASH scores of the affected elbow were not significantly different from those of the unaffected elbow (p = 0.140, p = 0.090, and p = 0.262, respectively). The mean degree of flexion was significantly lower in the affected elbow than in the unaffected elbow, but was still considered as functional (p = 0.001, > 100degrees in 33 of 38 patients). Two cases of articular step-offs (> 2 mm) were seen on follow-up CT scans, but not significantly higher in the affected elbow than in the unaffected elbow (p = 0.657). Binary logistic regression analysis revealed that only Association for Osteosynthesis (AO) type C3 fractures correlated with good/excellent functional outcome (p = 0.012). Complications occurred in 12 of the 38 patients, and the overall reoperation rate for complications was 10.5% (4 of 38 patients).

CONCLUSIONS:

Triangular fixation technique for bicolumn restoration was an effective and reliable method in treatment of distal humerus intercondylar fracture. This technique maintained articular congruency and restored both medial and lateral columns, resulting in good elbow function.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Postoperative Complications / Retrospective Studies / Range of Motion, Articular / Treatment Outcome / Intra-Articular Fractures / Fracture Fixation, Internal / Humeral Fractures Type of study: Observational study Limits: Adult / Aged / Aged80 / Female / Humans / Male Language: English Journal: Clinics in Orthopedic Surgery Year: 2016 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Postoperative Complications / Retrospective Studies / Range of Motion, Articular / Treatment Outcome / Intra-Articular Fractures / Fracture Fixation, Internal / Humeral Fractures Type of study: Observational study Limits: Adult / Aged / Aged80 / Female / Humans / Male Language: English Journal: Clinics in Orthopedic Surgery Year: 2016 Type: Article