Your browser doesn't support javascript.
loading
Reduced Field-of-View Diffusion-Weighted Magnetic Resonance Imaging of the Pancreas: Comparison with Conventional Single-Shot Echo-Planar Imaging
Korean Journal of Radiology ; : 1216-1225, 2015.
Article in English | WPRIM | ID: wpr-102546
ABSTRACT

OBJECTIVE:

To investigate the image quality (IQ) and apparent diffusion coefficient (ADC) of reduced field-of-view (FOV) di-ffusion-weighted imaging (DWI) of pancreas in comparison with full FOV DWI. MATERIALS AND

METHODS:

In this retrospective study, 2 readers independently performed qualitative analysis of full FOV DWI (FOV, 38 × 38 cm; b-value, 0 and 500 s/mm²) and reduced FOV DWI (FOV, 28 × 8.5 cm; b-value, 0 and 400 s/mm²). Both procedures were conducted with a two-dimensional spatially selective radiofrequency excitation pulse, in 102 patients with benign or malignant pancreatic diseases (mean size, 27.5 ± 14.4 mm). The study parameters included 1) anatomic structure visualization, 2) lesion conspicuity, 3) artifacts, 4) IQ score, and 5) subjective clinical utility for confirming or excluding initially considered differential diagnosis on conventional imaging. Another reader performed quantitative ADC measurements of focal pancreatic lesions and parenchyma. Wilcoxon signed-rank test was used to compare qualitative scores and ADCs between DWI sequences. Mann Whitney U-test was used to compare ADCs between the lesions and parenchyma.

RESULTS:

On qualitative analysis, reduced FOV DWI showed better anatomic structure visualization (2.76 ± 0.79 at b = 0 s/mm² and 2.81 ± 0.64 at b = 400 s/mm²), lesion conspicuity (3.11 ± 0.99 at b = 0 s/mm² and 3.15 ± 0.79 at b = 400 s/mm²), IQ score (8.51 ± 2.05 at b = 0 s/mm² and 8.79 ± 1.60 at b = 400 s/mm²), and higher clinical utility (3.41 ± 0.64), as compared to full FOV DWI (anatomic structure, 2.18 ± 0.59 at b = 0 s/mm² and 2.56 ± 0.47 at b = 500 s/mm²; lesion conspicuity, 2.55 ± 1.07 at b = 0 s/mm² and 2.89 ± 0.86 at b = 500 s/mm²; IQ score, 7.13 ± 1.83 at b = 0 s/mm² and 8.17 ± 1.31 at b = 500 s/mm²; clinical utility, 3.14 ± 0.70) (p 0.05). ADCs of adenocarcinomas (1.061 × 10⁻³ mm²/s ± 0.133 at reduced FOV and 1.079 × 10⁻³ mm²/s ± 0.135 at full FOV) and neuroendocrine tumors (0.983 × 10⁻³ mm²/s ± 0.152 at reduced FOV and 1.004 × 10⁻³ mm²/s ± 0.153 at full FOV) were significantly lower than those of parenchyma (1.191 × 10⁻³ mm²/s ± 0.125 at reduced FOV and 1.218 × 10⁻³ mm²/s ± 0.103 at full FOV) (p < 0.05).

CONCLUSION:

Reduced FOV DWI of the pancreas provides better overall IQ including better anatomic detail, lesion conspicuity and subjective clinical utility.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Pancreas / Pancreatic Diseases / Pancreatic Neoplasms / Retrospective Studies / Artifacts / Echo-Planar Imaging / Diffusion Magnetic Resonance Imaging / Diagnosis, Differential Type of study: Diagnostic study / Observational study / Qualitative research Limits: Adult / Aged / Female / Humans / Male Language: English Journal: Korean Journal of Radiology Year: 2015 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Pancreas / Pancreatic Diseases / Pancreatic Neoplasms / Retrospective Studies / Artifacts / Echo-Planar Imaging / Diffusion Magnetic Resonance Imaging / Diagnosis, Differential Type of study: Diagnostic study / Observational study / Qualitative research Limits: Adult / Aged / Female / Humans / Male Language: English Journal: Korean Journal of Radiology Year: 2015 Type: Article