ABSTRACT
OBJECTIVE: To investigate whether the low-tube-voltage (80-kVp), intermediate-tube-current (340-mAs) MDCT using the Iterative Reconstruction in Image Space (IRIS) algorithm improves lesion-to-liver contrast at reduced radiation dosage while maintaining acceptable image noise in the detection of hepatocellular carcinomas (HCC) in thin (mean body mass index, 24 +/- 0.4 kg/m2) adults. SUBJECTS AND METHODS: A phantom simulating the liver with HCC was scanned at 50-400 mAs for 80, 100, 120 and 140-kVp. In addition, fifty patients with HCC who underwent multiphasic liver CT using dual-energy (80-kVp and 140-kVp) arterial scans were enrolled. Virtual 120-kVP scans (protocol A) and 80-kVp scans (protocol B) of the late arterial phase were reconstructed with filtered back-projection (FBP), while corresponding 80-kVp scans were reconstructed with IRIS (protocol C). Contrast-to-noise ratio (CNR) of HCCs and abdominal organs were assessed quantitatively, whereas lesion conspicuity, image noise, and overall image quality were assessed qualitatively. RESULTS: IRIS effectively reduced image noise, and yielded 29% higher CNR than the FBP at equivalent tube voltage and current in the phantom study. In the quantitative patient study, protocol C helped improve CNR by 51% and 172% than protocols A and B (p < 0.001), respectively, at equivalent radiation dosage. In the qualitative study, protocol C acquired the highest score for lesion conspicuity albeit with an inferior score to protocol A for overall image quality (p < 0.001). Mean effective dose was 2.63-mSv with protocol A and 1.12-mSv with protocols B and C. CONCLUSION: CT using the low-tube-voltage, intermediate-tube-current and IRIS help improve lesion-to-liver CNR of HCC in thin adults during the arterial phase at a lower radiation dose when compared with the standard technique using 120-kVp and FBP.
Key words
Full text:
1
Index:
WPRIM
Main subject:
Algorithms
/
Iohexol
/
Radiographic Image Interpretation, Computer-Assisted
/
Tomography, X-Ray Computed
/
Regression Analysis
/
Retrospective Studies
/
Analysis of Variance
/
Carcinoma, Hepatocellular
/
Phantoms, Imaging
/
Contrast Media
Type of study:
Diagnostic_studies
/
Observational_studies
/
Prognostic_studies
/
Qualitative_research
Limits:
Female
/
Humans
/
Male
Language:
En
Journal:
Korean j. radiol
Year:
2012
Type:
Article