Your browser doesn't support javascript.
loading
Diagnosis of Coronary Restenosis Using Coronary Flow Reserve Measurements Obtained Through Transthoracic Doppler Echocardiography
Korean Circulation Journal ; : 325-330, 2008.
Article in Korean | WPRIM | ID: wpr-121056
ABSTRACT
BACKGROUND AND

OBJECTIVES:

Coronary flow reserve (CFR) decreases in the presence of significant coronary stenosis. Hence, CFR can be used for the detection of restenosis after percutaneous coronary intervention (PCI). However, because CFR can also be affected by other conditions such as endothelial dysfunction, microvascular damage, and left ventricular hypertrophy, the absolute value of CFR is not routinely used for detection of coronary restenosis. We hypothesized that changes in the value of CFR, rather than the absolute CFR value, are better correlated with restenosis in various clinical settings. SUBJECTS AND

METHODS:

We studied 99 patients (71 males/28 females, mean age 58+/-11 years) who underwent successful PCI of the left anterior descending artery. Pre-PCI diagnoses were as follows 37 unstable angina, 35 stable angina, 27 acute myocardial infarction. CFR using transthoracic Doppler was measured at 48 hours after PCI and at the time of follow-up angiography (6.0+/-1.5 months later). Coronary flow velocity was measured in the distal left anterior descending artery with a 7 MHz transducer (HDI 5,000, Philips, The Netherlands) at baseline and during intravenous infusion of adenosine (140 microgram.kg(-1).min(-1)). Mean diastolic coronary flow velocities from at least three cardiac cycles were averaged.

RESULTS:

CFRs in 69 patients without restenosis were 2.55+/-0.99 at 48 hours after PCI and 2.93+/-1.00 at follow-up (p50% in diameter stenosis) decreased significantly from 2.70+/-1.01 at 48 hours after PCI to 1.98+/-0.91 at follow-up (p<0.001). There was a significant difference in CFR change (ratio of CFR(followup)/CFR(initial)) between the two groups. CFR change had a better receiver operating characteristics (ROC) curve than absolute CFR for prediction of restenosis [area under the curve (AUC) for absolute CFR=0.76, AUC for CFR change=0.82].

CONCLUSION:

Restenosis after PCI leads to a significant decrease in CFR, even in the presence of variable baseline CFR values. Serial measurements of CFR can be used to detect restenosis after PCI.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Polyenes / Arteries / Transducers / Infusions, Intravenous / Angiography / Echocardiography / Echocardiography, Doppler / Adenosine / ROC Curve / Follow-Up Studies Type of study: Diagnostic study / Observational study / Prognostic study Limits: Female / Humans Language: Korean Journal: Korean Circulation Journal Year: 2008 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Polyenes / Arteries / Transducers / Infusions, Intravenous / Angiography / Echocardiography / Echocardiography, Doppler / Adenosine / ROC Curve / Follow-Up Studies Type of study: Diagnostic study / Observational study / Prognostic study Limits: Female / Humans Language: Korean Journal: Korean Circulation Journal Year: 2008 Type: Article